ArticleCancers2022
Development and In Vitro Assessment of a Novel Vacuum-Based Tissue-Holding Device for Laparoscopic and Robotic Kidney Cancer Operations.
Article in Cancers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this paper, we describe the development and evaluation of a novel tissue-holding device (THD) for use during robotic-assisted laparoscopic partial nephrectomy. The THD is a vacuum-based apparatus made of either 3D-printed polyethylene or stainless steel. The proximal end connects to suction tubing routed outside the body, while the distal end is conically shaped and designed to firmly interface with the tumor. Device feasibility studies were performed on six porcine kidneys, two porcine livers, and two embalmed human cadavers. A Likert-scale rating was used to assess device setup, suction, and tissue handling. Additional tests were performed using the daVinci Xi® robotic system. Finally, the holding force of the THD was assessed using different standard vacuum systems and pressure settings. In porcine tissue, the device setup, tissue suction, and handling were rated as "good". THD insertion and removal was uncomplicated. In a simulated transabdominal approach on fixed human cadavers, the device setup, suction, and tissue handling were also rated as "good". No macroscopic tissue compromise or device deterioration was noted. The handling and holding abilities using the daVinci Xi® robotic system were also rated "good". The device was able to successfully hold over 300 g of tissue at a suction pressure of -600 mmHg. The preliminary evaluation of the THD demonstrated satisfactory results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.