Development and In Vitro Assessment of a Novel Vacuum-Based Tissue-Holding Device for Laparoscopic and Robotic Kidney Cancer Operations.

Michael Gabi, Uwe Bieri, Venkat Ramakrishnan, Tilo Niemann, Antonio Nocito, Nadine Brader, Caroline Maake, Lukas John Hefermehl

Open access · goldAbstract read
In one paragraph

Article in Cancers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Michael GabiIndependent Researcher, Kawasaki 210-8577, Japan.
Uwe BieriDivision of Urology, Department of Surgery, Kantonsspital Baden, 5404 Baden, Switzerland.ORCID 0000-0002-7339-1458
Venkat RamakrishnanDivision of Urology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
Tilo NiemannInstitute for Radiology, Kantonsspital Baden, 5404 Baden, Switzerland.ORCID 0000-0002-5384-2522
Antonio NocitoDepartment of Surgery, Kantonsspital Baden, 5404 Baden, Switzerland.
Nadine BraderInstitute for Anatomy, University of Zurich, 8057 Zurich, Switzerland.
Caroline MaakeInstitute for Anatomy, University of Zurich, 8057 Zurich, Switzerland.
Lukas John HefermehlDivision of Urology, Department of Surgery, Kantonsspital Baden, 5404 Baden, Switzerland.ORCID 0000-0002-8467-5333
Kantonsspital Baden · CHUniversity of Zurich · CHBrigham and Women's Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, we describe the development and evaluation of a novel tissue-holding device (THD) for use during robotic-assisted laparoscopic partial nephrectomy. The THD is a vacuum-based apparatus made of either 3D-printed polyethylene or stainless steel. The proximal end connects to suction tubing routed outside the body, while the distal end is conically shaped and designed to firmly interface with the tumor. Device feasibility studies were performed on six porcine kidneys, two porcine livers, and two embalmed human cadavers. A Likert-scale rating was used to assess device setup, suction, and tissue handling. Additional tests were performed using the daVinci Xi® robotic system. Finally, the holding force of the THD was assessed using different standard vacuum systems and pressure settings. In porcine tissue, the device setup, tissue suction, and handling were rated as "good". THD insertion and removal was uncomplicated. In a simulated transabdominal approach on fixed human cadavers, the device setup, suction, and tissue handling were also rated as "good". No macroscopic tissue compromise or device deterioration was noted. The handling and holding abilities using the daVinci Xi® robotic system were also rated "good". The device was able to successfully hold over 300 g of tissue at a suction pressure of -600 mmHg. The preliminary evaluation of the THD demonstrated satisfactory results.

Indexed as

holding devicelaparoscopypartial nephrectomyrobotic surgeryvacuum

Identifiers

PMID36230544
PMCPMC9559531
OpenAlexW4297152855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.