Evidence map›Paper›PMID 36224636›Full record

ReviewJournal of orthopaedic surgery and research2022

Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures.

Dashuang Li, Rui Qiao, Na Yang, Kun Zhang, Yangjun Zhu, Zhe Song

Abstract readReview
In one paragraph

Review in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. [Comparative study on effectiveness of clavicular hook plate fixation in treatment of acromioclavicular joint dislocation and distal clavicle fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dashuang Li *Department of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China.
Rui Qiao *Department of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China.
Na YangDepartment of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China.
Kun ZhangDepartment of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China.
Yangjun ZhuDepartment of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China.
Zhe SongDepartment of Orthopaedic Trauma, Hong Hui Hospital, Xi'an Jiaotong University School of Medicine, Xi'an, 710054, Shaanxi, China. lidashuang524682@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDistal clavicular fracture is a shoulder joint injury that is common in clinical settings and is generally surgically treated using the clavicular hook plate technique with a confirmed curative effect. However, symptoms, such as shoulder abduction limitation, shoulder discomfort, and postoperative joint pain, may occur in some patients. To overcome these problems, after a previous study we developed an acromial height-measuring device and a new type of clavicular hook plate. This study aimed to investigate whether an acromial height-measuring device combined with an improved new-type clavicular hook plate can better reduce the incidence of complications and improve postoperative function. To provide patients with better treatment effects, an acromion gauge and clavicular hook plate are used.

methodsA retrospective analysis was performed on 81 patients with distal clavicular fractures admitted to our hospital. They were divided into experimental and control groups according to different plates, and the Constant-Murley score, visual analogue scale score, incidence of acromion osteolysis, and incidence of subacromial impingement syndrome were compared.

resultsCompared with the standard clavicular hook plate, the acromial height-measuring device combined with the new-type clavicular hook plate in the treatment of distal clavicle fractures has a lower incidence of subacromial impingement syndrome with better postoperative functional recovery and quality of life.

conclusionsWe considered the acromial height-measuring device combined with the new clavicular hook plate to be a safe and promising alternative to distal clavicular fractures.

Indexed as

Fractures, BoneShoulder Impingement SyndromeAcromionBone PlatesClavicleFracture Fixation, InternalHumansQuality of LifeRetrospective StudiesTreatment OutcomeAcromion osteolysisClavicular hook plateDistal clavicle fractureSubacromial impingement syndromeThe acromial height-measuring device

Identifiers

PMID36224636
PMCPMC9555107

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.