Evidence map›Paper›PMID 36219465›Full record

ArticleJournal of magnetic resonance imaging : JMRI2023

Multiparametric Magnetic Resonance Imaging of the Kidneys: Effects of Regional, Side, and Hydration Variations on Functional Quantifications.

Jie Chen, Zhen Zhang, Juan Liu, Chengjie Li, Meng Yin, Lisha Nie, Bin Song

Open access · greenAbstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Jie ChenDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Zhen ZhangDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Juan LiuDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Chengjie LiDepartment of Radiology, Chongqing Southeast Hospital, Chongqing, China.
Meng YinDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Lisha NieGE Healthcare, MR Research China, Beijing, China.
Bin SongDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.ORCID 0000-0002-7269-2101
Sichuan University · CNChongqing Emergency Medical Center · CNMayo Clinic · US

Funding

Magnetic Resonance ElastographyR37EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2016 to 2025
$4.0M
Magnetic Resonance ElastographyR01EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2003 to 2013
$3.1M
NIBIB NIH HHS R01 EB001981NIBIB NIH HHS R37 EB001981
6 · The paper itself

Abstract

backgroundTo standardize renal functional magnetic resonance imaging (MRI), it is important to understand the influence of side-to-side variation, regional variation within the organ, and hydration states in MRI and to search for variables that are not affected by those variations. PURPOSE: To assess MRI-based biomarkers for characterizing the kidney in healthy volunteers while considering variations in anatomic factors and hydration states. STUDY TYPE: Prospective. SUBJECTS: Twenty-five healthy volunteers (15 females and 10 males, median age 25 years). FIELD STRENGTH/SEQUENCE: 3.0 T intravoxel incoherent motion diffusion-weighted imaging, arterial spinning labeling imaging, blood oxygenation level dependent imaging, and three-dimensional MR elastography. ASSESSMENT: Functional variables were measured before and after water challenge. Regions of interest were manually drawn by two investigators (JC and ZZ, with 8- and 5-year experiences in abdominal radiology) in the cortex, the medulla, and the entire kidney. The medulla/cortex ratio was calculated. STATISTICAL TESTS: Paired t-test or Wilcoxon signed rank test; interobserver correlation coefficient; repeatability coefficients; Spearman's correlation; significance level: P < 0.05.

resultsDiffusion parameters were only subject to regional variation. R2*, RBF, and renal stiffness (RS) showed regional variation, side variation, and dependence on hydration states. For each side and hydration state, the cortex showed significantly higher standard apparent diffusion coefficient (sADC), higher true diffusion (D), lower R2*, and lower RS than the medulla. For each region at baseline, the left kidney showed significantly higher R2*, higher RS, and lower renal blood flow (RBF) than the right kidney. For each region and side, RS and RBF increased significantly while R2* decreased significantly after water intake. After introducing the intrinsic regional difference, significantly higher medulla/cortex ratio of RS remained after water intake except for RS@90 Hz in the right kidney. DATA

conclusionRenal multiparametric MRI quantifications were affected by regional variation, side variation, and hydration states. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

Indexed as

Multiparametric Magnetic Resonance ImagingAdultDiffusion Magnetic Resonance ImagingFemaleHumansKidneyMagnetic Resonance ImagingMaleProspective Studiesanatomic variationarterial spinning labeling imagingblood oxygenation level dependent imaginghydration statesintravoxel incoherent motion diffusion-weighted imagingkidneymagnetic resonance elastography

Identifiers

PMID36219465
PMCPMC10079549
OpenAlexW4304203230

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.