Evidence map›Paper›PMID 36216797›Full record

ArticleLight, science & applications2022

Raster-scanning Donut simplifies MINFLUX and provides alternative implement on other scanning-based microscopes.

Xinzhu Xu, Shu Jia, Peng Xi

Abstract read
In one paragraph

Article in Light, science & applications, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Xinzhu XuDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing, 100871, China.
Shu JiaWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, 30332, USA.ORCID http://orcid.org/0000-0001-6854-7537
Peng XiDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing, 100871, China. xipeng@pku.edu.cn.ORCID http://orcid.org/0000-0001-6626-4840

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A donut excitation moves around a single molecule with a zigzag configuration lattice by lattice. Such a method implemented in scanning fluorescence microscopy simplifies the conventional MINFLUX process. Consisting of hollow zero-intensity excitation, single-pixel detection, time-correlated single photon counting, and drift stabilization, the system achieves localization precision and resolution very close to conventional MINFLUX theoretically and experimentally. An averaged high-SNR reference, and pixel-registered intensity from a single molecule is essential to reconstruct localization in maximum likelihood estimation. With performance reaching nearly conventional MINFLUX's, the proposed raster-scanning MINFLUX can inspire researchers expertized in STED or confocal setup to quickly transform to MINFLUX and develop for further exploring on bio-specimens or optical applications.

Identifiers

PMID36216797
PMCPMC9550861

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.