Evidence map›Paper›PMID 36215251›Full record

ArticlePloS one2022

Cost-effective micro-CT system for non-destructive testing of titanium 3D printed medical components.

Santiago Fabian Cobos, Christopher James Norley, Steven Ingo Pollmann, David Wayne Holdsworth

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Santiago Fabian CobosDepartment of Medical Biophysics, Schulich School of Medicine & Dentistry, The University of Western Ontario, London, Ontario, Canada.ORCID 0000-0002-7239-3240
Christopher James NorleyImaging Research Laboratories, Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada.
Steven Ingo PollmannImaging Research Laboratories, Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada.
David Wayne HoldsworthDepartment of Medical Biophysics, Schulich School of Medicine & Dentistry, The University of Western Ontario, London, Ontario, Canada.

Funding

CIHR FDN 148474
6 · The paper itself

Abstract

Micro-CT imaging can be used as an effective method for non-destructive testing (NDT) of metal 3D printed parts-including titanium biomedical components fabricated using laser powder-bed-fusion (LPBF). Unfortunately, the cost of commercially available micro-CT scanners renders routine NDT for biomedical applications prohibitively expensive. This study describes the design, manufacturing, and implementation of a cost-effective scanner tailored for NDT of medium-size titanium 3D printed biomedical components. The main elements of the scanner; which include a low-energy (80 kVp) portable x-ray unit, and a low-cost lens-coupled detector; can be acquired with a budget less than $ 11000 USD. The low-cost detector system uses a rare-earth phosphor screen, lens-coupled to a dSLR camera (Nikon D800) in a front-lit tilted configuration. This strategy takes advantage of the improved light-sensitivity of modern full-frame CMOS camera sensors and minimizes source-to-detector distance to maximize x-ray flux. The imaging performance of the system is characterized using a comprehensive CT quality-assurance phantom, and two titanium 3D-printed test specimens. Results show that the cost-effective scanner can survey the porosity and cracks in titanium parts with thicknesses of up to 13 mm of solid metal. Quantitatively, the scanner produced geometrically stable reconstructions, with a voxel size of 118 μm, and noise levels under 55 HU. The cost-effective scanner was able to estimate the porosity of a 17 mm diameter titanium 3D-printed cylindrical lattice structure, with a 0.3% relative error. The proposed scanner will facilitate the implementation of titanium LPBF-printed components for biomedical applications by incorporating routine cost-effective NDT as part of the process control and validation steps of medical-device quality-management systems. By reducing the cost of the x-ray detector and shielding, the scan cost will be commensurate with the overall cost of the validated component.

Indexed as

Printing, Three-DimensionalTitaniumCost-Benefit AnalysisPhantoms, ImagingPowdersX-Ray MicrotomographyPowdersTitanium

Identifiers

PMID36215251
PMCPMC9550031

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.