Evidence map›Paper›PMID 36212207›Full record

ArticleJournal of medical physics

Evaluation of Surface Dose and Commissioning of Compensator-Based Total Body Irradiation.

Bharath Pandu, D Khanna, P Mohandass, Hima Ninan, Rajadurai Elavarasan, Saro Jacob, Goutham Sunny

Open access · diamondAbstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Bharath PanduDepartment of Applied Physics, Karunya Institute of Technology and Sciences, Coimbatore, Tamil Nadu, India.
D KhannaDepartment of Applied Physics, Karunya Institute of Technology and Sciences, Coimbatore, Tamil Nadu, India.
P MohandassDepartment of Radiation Oncology, Fortis Hospital, Mohali, Punjab, India.
Hima NinanDepartment of Radiotherapy, Bangalore Baptist Hospital, Bengaluru, Karnataka, India.
Rajadurai ElavarasanDepartment of Radiotherapy, Bangalore Baptist Hospital, Bengaluru, Karnataka, India.
Saro JacobDepartment of Radiotherapy, Bangalore Baptist Hospital, Bengaluru, Karnataka, India.
Goutham SunnyDepartment of Radiotherapy, Bangalore Baptist Hospital, Bengaluru, Karnataka, India.
Bangalore Baptist Hospital · INKarunya University · INFortis Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The aim of the current study is to commission compensator-based total body irradiation (TBI) and to compare surface dose using percentage depth dose (PDD) while varying the distance between beam spoiler and phantom surface. Materials and Methods: TBI commissioning was performed on Elekta Synergy® Platform linear accelerator for bilateral extended source to surface distance treatment technique. The PDD was measured by varying the distance (10 cm, 20 cm, 30 cm, and 40 cm) between the beam spoiler and the phantom surface. Beam profile and half-value layer (HVL) measurement were carried out using the FC65 ion-chamber. Quality assurance (QA) was performed using an in-house rice-flour phantom (RFP). Results: An increase in Dmax and surface dose was observed when beam spoiler was moved away from the phantom surface. The flatness and symmetry of the beam profile were calculated. The HVL of Perspex and aluminum is 17 cm and 8 cm, respectively. The calculated dose of each region was compared to the measured dose on the RFP with IVD, and the findings showed that the variation was <4.7% for both Perspex and Aluminum compensators. Conclusion: The commissioning of the compensator-based TBI technique was performed and its QA measurements were carried out. The Mayneord factor corrected PDD and measured PDD values were compared. The results are well within the clinical tolerance limit. This study concludes that 10 cm -20 cm is the optimal distance from the beam spoiler to phantom surface to achieve prescribed dose to the skin.

Indexed as

Beam spoiler distancecompensator-based total body irradiationsurface dose analysistotal body irradiation

Identifiers

PMID36212207
PMCPMC9542993
OpenAlexW4289756373

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.