Different glucose analyzers report different glucose concentration values in term newborns.

Rina P Duke, Shasha Bai, Joshua A Bornhorst, Nahed O ElHassan, Jeffrey R Kaiser

Open access · goldAbstract read
In one paragraph

Article in Frontiers in pediatrics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 1 country.

Rina P DukeDepartment of Pediatrics (Neonatology), Lehigh Valley Reilly Children's Hospital, Allentown, PA, United States.
Shasha BaiPediatrics Biostatistics Core, Department of Pediatrics, Emory University School of Medicine, Atlanta, GA, United States.
Joshua A BornhorstDepartment of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, United States.
Nahed O ElHassanDepartment of Pediatrics (Neonatal-Perinatal Medicine), University of Arkansas for Medical Sciences, Little Rock, AR, United States.
Jeffrey R KaiserDepartments of Pediatrics (Neonatal-Perinatal Medicine) and Obstetrics and Gynecology, Penn State Children's Hospital, Hershey, PA, United States.
Emory University · USLehigh Valley Hospital-Pocono · USMayo Clinic in Arizona · USPenn State Milton S. Hershey Medical Center · USUniversity of Arkansas for Medical Sciences · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The American Academy of Pediatrics and Pediatric Endocrine Society neonatal hypoglycemia guidelines based their glucose concentration treatment thresholds on studies that predominantly used Beckman and Yellow Springs Glucose Oxidase Analyzers. Currently, a majority (76%) of U.S. hospital laboratories utilizing glucose oxidase methodology use Vitros Methods: To determine if there is similar instrument bias between Beckman and Vitros Analyzers in reported glucose concentrations from term newborns, we compared plasma glucose concentrations measured within the first 3 h after birth by Beckman vs. Vitros Analyzers in a total of 1,987 newborns (Beckman Results: The non-linear patterns of initial glucose concentrations (during the first 3 h after birth) as measured by Beckman and Vitros Analyzers paralleled each other with no overlap of the fit spline curve 95% confidence intervals, with an approximate +5 mg/dL constant bias. Additionally, in method comparison studies performed in the Chemistry Laboratory on adult samples, there was a +4.2-7.4 mg/dL measured glucose bias for the Beckman vs. Vitros Analyzer. Conclusion: Glucose concentrations from term, appropriate size for gestational age newborns were about 5 mg/dL higher when measured by Beckman vs. Vitros Analyzers. Perhaps, concentrations of 45 mg/dL reported from Beckman Analyzers may be equivalent to 40 mg/dL from Vitros Analyzers. When managing neonatal hypoglycemia, it is important to know which analyzer was used and whether adjusting for potential instrument bias is necessary when following published guidelines.

Indexed as

glucoseglucose analyzerguidelineneonatal hypoglycemianewborn

Identifiers

PMID36210937
PMCPMC9532546
OpenAlexW4296737965

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.