ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2022
[Nonlocal low-rank and sparse matrix decomposition for low-dose cerebral perfusion CT image restoration].
Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo present a nonlocal low-rank and sparse matrix decomposition (NLSMD) method for low-dose cerebral perfusion CT image restoration.
methodsLow-dose cerebral perfusion CT images were first partitioned into a matrix, and the low- rank and sparse matrix decomposition model was constructed to obtain high-quality low-dose cerebral perfusion CT images. The cerebral hemodynamic parameters were calculated from the restored high-quality CT images.
resultsIn the phantom study, the average structured similarity (SSIM) value of the sequential images obtained by filtered back-projection (FBP) algorithm was 0.9438, which was increased to 0.9765 using the proposed algorithm; the SSIM values of cerebral blood flow (CBF) and cerebral blood volume (CBV) map obtained by FBP algorithm were 0.7005 and 0.6856, respectively, which were increased using the proposed algorithm to 0.7871 and 0.7972, respectively.
conclusionThe proposed method can effectively suppress noises in low-dose cerebral perfusion CT images to obtain accurate cerebral hemodynamic parameters.