Evidence map›Paper›PMID 36210177›Full record

ArticleJournal of applied clinical medical physics2023

A component method to delineate surgical spine implants for proton Monte Carlo dose calculation.

Chih-Wei Chang, Serdar Charyyev, Joseph Harms, Roelf Slopsema, Jonathan Wolf, Daniel Refai, Tim Yoon, Mark W McDonald, Jeffrey D Bradley, Shuai Leng and 3 more

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Deep learning-based Fast Volumetric Image Generation for Image-guided Proton Radiotherapy.IEEE transactions on radiation and plasma medical sciences · 2024
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 3 institutions in 1 country.

Chih-Wei ChangDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Serdar CharyyevDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Joseph HarmsDepartment of Radiation Oncology, University of Alabama, Birmingham, Alabama, USA.
Roelf SlopsemaDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Jonathan WolfDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Daniel RefaiDepartment of Neurosurgery, Emory University, Atlanta, Georgia, USA.
Tim YoonDepartment of Orthopaedics, Emory University, Atlanta, Georgia, USA.
Mark W McDonaldDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Jeffrey D BradleyDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Jun ZhouDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Xiaofeng YangDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Liyong LinDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
Emory University · USMayo Clinic · USUniversity of Alabama at Birmingham · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMetallic implants have been correlated to local control failure for spinal sarcoma and chordoma patients due to the uncertainty of implant delineation from computed tomography (CT). Such uncertainty can compromise the proton Monte Carlo dose calculation (MCDC) accuracy. A component method is proposed to determine the dimension and volume of the implants from CT images.

methodsThe proposed component method leverages the knowledge of surgical implants from medical supply vendors to predefine accurate contours for each implant component, including tulips, screw bodies, lockers, and rods. A retrospective patient study was conducted to demonstrate the feasibility of the method. The reference implant materials and samples were collected from patient medical records and vendors, Medtronic and NuVasive. Additional CT images with extensive features, such as extended Hounsfield units and various reconstruction diameters, were used to quantify the uncertainty of implant contours.

resultsFor in vivo patient implant estimation, the reference and the component method differences were 0.35, 0.17, and 0.04 cm

conclusionsA component method was developed and demonstrated using phantom and patient studies with implants. The proposed method provides more accurate implant characterization for proton MCDC and can potentially enhance the treatment quality for proton therapy. The current proof-of-concept study is limited to the implant characterization for lumbar spine. Future investigations could be extended to cervical spine and dental implants for head-and-neck patients where tight margins are required to spare organs at risk.

Indexed as

ProtonsProton TherapyAlgorithmsHumansMonte Carlo MethodPhantoms, ImagingRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective StudiesProtonsMonte Carlo dose calculationproton therapysurgical implant delineation

Identifiers

PMID36210177
PMCPMC9859997
OpenAlexW4303946536

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.