Evidence map›Paper›PMID 36209439›Full record

ArticleArchives of orthopaedic and trauma surgery2023

Medial proximal tibial resorption after total knee arthroplasty according to the design of the cobalt chrome tibial baseplate.

Sang Jun Song, Hyun Woo Lee, Cheol Hee Park

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sang Jun SongDepartment of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 23 Kyunghee-daero, Dongdaemun-gu, Seoul, 130-872, Korea.
Hyun Woo LeeDepartment of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 23 Kyunghee-daero, Dongdaemun-gu, Seoul, 130-872, Korea.
Cheol Hee ParkDepartment of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 23 Kyunghee-daero, Dongdaemun-gu, Seoul, 130-872, Korea. rdohead@hanmail.net.ORCID http://orcid.org/0000-0001-8297-6872
Kyung Hee University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeA new tibial baseplate of the cobalt-chrome (CoCr) prosthesis has an enhanced design with additional cement pockets and undersurface with increased roughness compared with the original baseplate. This study aimed to compare the incidence of medial proximal tibial resorption (MPTR) in total knee arthroplasties (TKAs) with the original and new CoCr tibial baseplates.

methodsEach of 200 posterior stabilized TKAs with the original (Group O) and new (Group N) CoCr tibial baseplates with a minimum follow-up period of 2 years were retrospectively reviewed. The matches were made according to age, sex, body mass index, and severity of varus deformity. The occurrence of MPTR was investigated with a radiograph at 2 years postoperatively. MPTR was categorized as type U (resorption under the tibial baseplate; associated with stress shielding), C (resorption around the penetrated cement under the baseplate; associated with thermal necrosis), and M (resorption on the medial tibial cortex without extension to the baseplate; associated with bony devascularization).

resultsThe incidence of MPTR was 35% in group O and 24% in group N (p = 0.021) at postoperative 2 years. The U type of MPTR occurred more frequently in group O (26 vs. 15%, p = 0.009). There were no significant differences in the incidence of types C and M MPTR.

conclusionThe modified design of the CoCr tibial baseplate affected the incidence of MTPR. The new tibial baseplate was more advantageous in preventing MPTR than the original baseplate in TKAs using the CoCr prosthesis. LEVEL OF EVIDENCE: III.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisBone CementsChromium AlloysCobaltHumansKnee JointProsthesis DesignRetrospective StudiesTibiaBone CementsChromium AlloysCobaltArthroplastyBone resorptionKneeStress shieldingTibial baseplate

Identifiers

PMID36209439
OpenAlexW4303856963

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.