A facile method for generating polypyrrole microcapsules and their application in electrochemical sensing.

Piyanut Pinyou, Vincent Blay, Jirawan Monkrathok, Pattanaphong Janphuang, Kantapat Chansaenpak, Jaruwan Pansalee, Sireerat Lisnund

Abstract read
In one paragraph

Article in Mikrochimica acta, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Piyanut PinyouSchool of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima, 30000, Thailand. piyanutp@sut.ac.th.ORCID http://orcid.org/0000-0001-7978-1898
Vincent BlayDepartment of Microbiology and Environmental Toxicology, University of California at Santa Cruz, Santa Cruz, CA, 95064, USA. vroger@ucsc.edu.ORCID http://orcid.org/0000-0001-9602-2375
Jirawan MonkrathokSynchrotron Light Research Institute, 111 University Ave., Nakhon Ratchasima, 30000, Thailand.
Pattanaphong JanphuangSynchrotron Light Research Institute, 111 University Ave., Nakhon Ratchasima, 30000, Thailand.
Kantapat ChansaenpakNational Nanotechnology Center, National Science and Technology Development Agency, Thailand Science Park, Pathum Thani, 12120, Thailand.ORCID http://orcid.org/0000-0002-5462-9897
Jaruwan PansaleeSchool of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima, 30000, Thailand.
Sireerat LisnundDepartment of Applied Chemistry, Faculty of Science and Liberal Arts, Rajamangala University of Technology Isan, 744, Suranarai Rd., Nakhon Ratchasima, 30000, Thailand.

Funding

National Nanotechnology Center (TH) P2250217National Research Council of Thailand N42A650389National Science, Research and Innovation Fund (TH) 10636National Science, Research and Innovation Fund (TH) 90464
6 · The paper itself

Abstract

A facile and rapid strategy to generate polypyrrole microcapsules is reported. The strategy is compatible with a vortex mixer and with a microfluidic chip for droplet generation, allowing a > 100-fold reduction in particle size. The sub-micron particle sizes obtained can also be tuned to some extent based on the chip geometry. The capsules can be kept stably in solution and can be transferred onto electrochemical devices. As an application example, we casted the polypyrrole capsules generated onto screen-printed electrodes, leading to a significant increase in their electroactive surface area and capacitance. The electrodes were further modified with glucose dehydrogenase (GDH) to fabricate glucose biosensors. The introduction of polypyrrole microcapsules increased the dynamic range of the glucose sensor to ca. 300% compared with that of the electrode without polypyrrole microcapsules. The resulting glucose sensor is operated at a constant applied potential of 0.20 V vs. Ag/AgCl (3 M KCl) in an air-equilibrated electrolyte. At this potential, the sensor showed a linear range from 1.0 to 9.0 mM glucose with a sensitivity of 3.23 µA cm

Indexed as

PolymersPyrrolesCapsulesGlucoseGlucose 1-DehydrogenaseReproducibility of ResultsSolventsSurface-Active AgentsCapsulesGlucoseGlucose 1-DehydrogenasePolymerspolypyrrolePyrrolesSolventsSurface-Active AgentsBiosensorCapsule immobilizationChronoamperometryEncapsulationMicrofluidicsScreen-printed electrodes

Identifiers

PMID36208339
PMCPMC9547802

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.