Evidence map›Paper›PMID 36205904›Full record

ArticleMethods in molecular biology (Clifton, N.J.)2023

Determination of Catecholamines in a Small Volume (25 μL) of Plasma from Conscious Mouse Tail Vein.

Kechun Tang, Sushil K Mahata

Open access · greenAbstract read
In one paragraph

Article in Methods in molecular biology (Clifton, N.J.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
3.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Kechun TangVA San Diego Healthcare System, San Diego, CA, USA.
Sushil K MahataVA San Diego Healthcare System, San Diego, CA, USA. smahata@health.ucsd.edu.
VA San Diego Healthcare System · US

Funding

Chromogranin A is an aging risk factorR21AG078635 · NIA · VETERANS MEDICAL RESEARCH FDN/SAN DIEGO · PI GHOSH, GOURISANKAR, MAHATA, SUSHIL K · 2023 to 2024
$413k
Catestatin improves glucose homeostasis and insulin sensitivity in diet-induced obese miceI01BX003934 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI MAHATA, SUSHIL K · 2018 to 2021
–
ShEEP Request for ACQUITY UPLC H-Class PLUS Bio SystemIS1BX005048 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI MAHATA, SUSHIL K · 2019 to 2019
–
BLRD VA I01 BX003934BLRD VA IS1 BX005048NIA NIH HHS R21 AG078635RRD VA I21 RX004398
6 · The paper itself

Abstract

The determination of plasma catecholamine levels is commonly used as a measure of the sympathetic nervous system's response to stress and is highly important for diagnosis, therapy, and prognosis of cardiovascular diseases, catecholamine-secreting tumors arising from the chromaffin cells of the sympathoadrenal system, and affective disorders. Diseases in which catecholamines are significantly elevated include pheochromocytoma, Parkinson's disease, Alzheimer's disease, neuroblastoma, ganglioneuroblastoma, von Hippel-Lindau disease, baroreflex failure, chemodectina (nonchromaffin paraganglioma), and multiple endocrine neoplasia. Plasma norepinephrine levels provide a guide to prognosis in patients with stable, chronic, and congestive heart diseases. The method described here for the determination of plasma catecholamines is based on the principle that plasma catecholamines are selectively adsorbed on acid-washed alumina at pH 8.7 and then eluted at a pH between 1.0 and 2.0. Upon injection, catecholamines in elutes were separated by a reversed phase C-18 column. After separation, the catecholamines present within the mobile phase enter the electrochemical detector. Electrochemical detection occurs because electroactive compounds oxidize at a certain potential and thereby liberate electrons that create measurable current. Catecholamines readily form quinones under these conditions, get oxidized, release two electrons, and create current. The electrochemical detector detects this electrical current that linearly correlates to the catecholamine concentration loaded into the ultra-performance liquid chromatography instrument. A 15-min mixing time during the adsorption and desorption steps was found to be optimal. If the washing step was omitted, the catecholamines could not be eluted from the acid-washed alumina. To prevent dilution, the alumina had to be centrifuged and not aspirated to dryness after the washing step. We report here that by changing the range in the electrochemical detector, plasma catecholamines were measured with only 12.5 μL of plasma and more reliably with 25 μL of plasma. The detection limit was 1 ng/mL. This assay method is very useful as blood can be collected from the tail vein in a conscious mouse and the same mouse can be used for time-dependent or age-dependent studies.

Indexed as

Adrenal Gland NeoplasmsCatecholaminesAluminum OxideAnimalsChromatography, High Pressure LiquidMiceNorepinephrineQuinonesTailAluminum OxideCatecholaminesNorepinephrineQuinonesCatecholamineChromatographyDopamineElectrochemical detectionEpinephrineNorepinephrinePlasma

Identifiers

PMID36205904
PMCPMC10798352
OpenAlexW4303432672

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.