Evidence map›Paper›PMID 36205761›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs.

Anni Rajamäki, Mika Niemeläinen, Mika Junnila, Lari Lehtovirta, Mari Karsikas, Ville Ponkilainen, Antti Eskelinen

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Thicker Polyethylene Bearings Offer Equivalent Patient-reported Outcomes.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Anni RajamäkiCoxa Hospital for Joint Replacement, Niveltie 4, 33520, Tampere, Finland. anni.rajamaki@tuni.fi.ORCID http://orcid.org/0000-0001-8046-2747
Mika NiemeläinenCoxa Hospital for Joint Replacement, Niveltie 4, 33520, Tampere, Finland.
Mika JunnilaCoxa Hospital for Joint Replacement, Niveltie 4, 33520, Tampere, Finland.
Lari LehtovirtaCoxa Hospital for Joint Replacement, Niveltie 4, 33520, Tampere, Finland.
Mari KarsikasCoxa Hospital for Joint Replacement, Niveltie 4, 33520, Tampere, Finland.
Ville PonkilainenDepartment of Surgery, Central Finland Central Hospital Nova, Hoitajantie 3, 40620, Jyväskylä, Finland.
Antti EskelinenCoxa Hospital for Joint Replacement, Niveltie 4, 33520, Tampere, Finland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study investigates whether thicker (PE) inserts lead to a greater risk for revision after TKA. The differences between the TKA designs of three manufacturers (NexGen, PFC Sigma, Triathlon) are also compared.

methodsA total of 7643 primary TKA surgeries were included. PE inserts were divided into two groups-"thick PE inserts" with a thickness of 13 mm (mm) or more and "standard PE inserts" with a thickness of less than 13 mm. Three cruciate-retaining (CR) TKA designs (NexGen, PFC Sigma, Triathlon) were included in the study. The differences in failure rates between groups were investigated using Kaplan-Meier survival curves and Cox regression model with hazard ratios (HR). Failure rates were investigated short-term (< 2 years) and long-term (the whole follow-up period). The TKA designs were analysed both together and separately.

resultsDuring the whole follow-up period, there were 184 (2.4%) aseptic revisions. The thick PE insert group showed an increased risk for revision compared to the standard PE insert group in both short-term (< 2 years; HR 2.0, CI 1.3 to 3.2) and long term (> 2 years; HR 1.6, CI 1.1 to 2.3) follow-up. The highest revision rate was observed in patients who received the Triathlon TKA with a thicker PE insert (HR 2.6, CI 1.2 to 5.7).

conclusionThe results indicate that thicker PE inserts are associated with increased risk for revision in primary TKA. Further research is required to ascertain whether more conformed PE inserts or constrained knee designs instead of thick CR inserts will ultimately lead to better clinical outcomes. LEVEL OF EVIDENCE: III.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisHumansKnee JointPolyethyleneProsthesis DesignProsthesis FailureReoperationPolyethyleneAseptic looseningCruciate-retaining implantInstabilityPolyethylene insertRevision riskSurvivalThicknessTKA

Identifiers

PMID36205761
PMCPMC9957842

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.