ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023
Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Can a Total Knee System Providing 1 mm Increment of Polyethylene Insert Thickness Offer a Clinical Benefit?Medicina (Kaunas, Lithuania) · 2024Trial
- Precision and Accuracy of Polyethylene Thickness in Total Knee Arthroplasty: A Comparison of Conventional Measured Resection and Robotic-Assisted Techniques.Arthroplasty today · 2026Article
- Total knee arthroplasty for valgus deformity correction using "inverted cruciform release": technique and outcomes.BMC musculoskeletal disorders · 2026Article
- Extra-long femoral heads as a surrogate marker for revision risk in primary total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2026Article
- Thicker Polyethylene Bearings Offer Equivalent Patient-reported Outcomes.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026Article
- Article
- Lateral femoral epicondylar osteotomy during total knee arthroplasty for osteoarthritis with severe correctable intra-articular varus and lateral laxity: A case-report.Journal of clinical orthopaedics and trauma · 2025Article
- CORR Synthesis: What Is the Role of Robotic-assisted Technology in Knee Arthroplasty?Clinical orthopaedics and related research · 2025Article
- Survival of primary total knee arthroplasty in a modern anatomic implant with and without a short stem extension.Archives of orthopaedic and trauma surgery · 2025Article
- Robotic assisted TKA may allow for smaller polyethylene liner sizes compared to manual TKA with simultaneous removal of Hardware.Scientific reports · 2025Article
- Robotic-Assisted Total Knee Arthroplasty Improves Accuracy and Reproducibility of the Polyethylene Insert Thickness Compared to Manual Instrumentation or Navigation: A Retrospective Cohort Study.Arthroplasty today · 2024Article
- Manual Stress and Gap Spacer Systematically Underestimate Intraoperative Joint Gaps Compared with a Tensor Device in Robotic-Assisted Total Knee Arthroplasty.JB & JS open accessArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study investigates whether thicker (PE) inserts lead to a greater risk for revision after TKA. The differences between the TKA designs of three manufacturers (NexGen, PFC Sigma, Triathlon) are also compared.
methodsA total of 7643 primary TKA surgeries were included. PE inserts were divided into two groups-"thick PE inserts" with a thickness of 13 mm (mm) or more and "standard PE inserts" with a thickness of less than 13 mm. Three cruciate-retaining (CR) TKA designs (NexGen, PFC Sigma, Triathlon) were included in the study. The differences in failure rates between groups were investigated using Kaplan-Meier survival curves and Cox regression model with hazard ratios (HR). Failure rates were investigated short-term (< 2 years) and long-term (the whole follow-up period). The TKA designs were analysed both together and separately.
resultsDuring the whole follow-up period, there were 184 (2.4%) aseptic revisions. The thick PE insert group showed an increased risk for revision compared to the standard PE insert group in both short-term (< 2 years; HR 2.0, CI 1.3 to 3.2) and long term (> 2 years; HR 1.6, CI 1.1 to 2.3) follow-up. The highest revision rate was observed in patients who received the Triathlon TKA with a thicker PE insert (HR 2.6, CI 1.2 to 5.7).
conclusionThe results indicate that thicker PE inserts are associated with increased risk for revision in primary TKA. Further research is required to ascertain whether more conformed PE inserts or constrained knee designs instead of thick CR inserts will ultimately lead to better clinical outcomes. LEVEL OF EVIDENCE: III.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.