Evidence map›Paper›PMID 36201009›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design.

Abigail E Niesen, Anna L Garverick, Stephen M Howell, Maury L Hull

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abigail E NiesenDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA, 95616, USA.
Anna L GarverickDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA, 95616, USA.
Stephen M HowellDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA, 95616, USA.
Maury L HullDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA, 95616, USA. mlhull@ucdavis.edu.ORCID http://orcid.org/0000-0001-8305-4589

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVarus alignment of the tibial baseplate and limb > 3° might adversely affect baseplate fixation after total knee arthroplasty (TKA), especially for unrestricted kinematically aligned (KA) TKA which aligns a majority of baseplates in varus. The purposes of this study were to determine whether baseplate migration at 1 year (1) was significantly less than a stability limit of 0.5 mm, (2) increased over time, and (3) was related to varus alignment of the baseplate and limb after unrestricted KA TKA.

methodsThirty-five patients underwent unrestricted KA TKA using a fixed-bearing, cemented, medial conforming tibial insert with posterior cruciate ligament retention. Using model-based radiostereometric analysis, maximum total point motion (MTPM) (i.e., largest displacement on the baseplate) was computed at 6 weeks, 3 months, 6 months, and 1 year postoperatively relative to the day of surgery. Baseplate and limb alignment were measured postoperatively on long-leg CT scanograms.

resultsAt 1 year, mean MTPM of 0.35 mm was significantly less than the 0.5 mm stability limit (p = 0.0002). Mean MTPM did not increase from 6 weeks to 1 year (p = 0.3047). Notably, 89% (31/35) of tibial baseplates and 46% (16/35) of limbs were > 3° varus. Baseplate and limb alignment had no relationship to MTPM at 1 year (|r|≤ 0.173, p ≥ 0.3276).

conclusionLow and non-progressive tibial baseplate migration 1 year after unrestricted KA TKA with a medial conforming design should allay any concern that unrestricted KA TKA increases risk of baseplate loosening due to varus alignment of the baseplate and limb. LEVEL OF EVIDENCE: Level II, therapeutic prospective cohort study.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeBiomechanical PhenomenaHumansKnee JointProspective StudiesTibiaAseptic looseningBaseplate stability, stable baseplateMaximum total point motionMigration stability limitModel-based radiostereometric analysisNonprogressive migrationTKA alignment techniqueTKA outcomesVarus baseplate alignment

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.