ArticleJournal of orthopaedic case reports2022
TresLock for Unstable Proximal Femoral Fractures: Morphological Compatibility and Clinical Results: A Case Series.
Article in Journal of orthopaedic case reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: A new device, TresLock (KISCO DIR Co., Ltd., Kobe), has been used for the treatment of unstable proximal femoral fractures and was designed based on Japanese anatomical characteristics. It has three sliding hip screws with one side plate. The angle of all screws relative to the plate has been set to 128°, and each hip screw has a short thread (15 mm) to prevent crossing of the fracture line. In this study, we evaluated the morphological compatibility of TresLock. Methods: We treated 10 patients with hip fractures using TresLock at our institution between September 2016 and December 2017. The average age of the patients was 83.8 years (range, 73-93 years). Fractures included five proximal neck transcervical shear fractures (Orthopaedic Trauma Association [OTA] type-31B2.3, Pauwels III) and five basicervical fractures (OTA type-31B3). The clinical course and three-dimensional computed tomography were evaluated postoperatively. Results: In all cases, all three screws were inserted within the femoral neck. The screws were inserted at an axis of 2.5 ± 1.3° varus to the femoral neck axis. The distance from the subcapital line to the three (proximal-anterior, proximal-posterior, and distal) screw thread ends was 12.0 ± 1.8 mm, 10.4 ± 2.4 mm, and 11.6 ± 4.0 mm, respectively and was sufficient to actuate compression force. However, one case (Pauwels III) required reoperation because of non-union. Conclusion: Careful follow-up is needed, but TresLock shows good anatomical compatibility for femurs among the Japanese population.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.