ArticleThe Journal of hospital infection2023

Portable HEPA filtration successfully augments natural-ventilation-mediated airborne particle clearance in a legacy design hospital ward.

M Fennelly, S Hellebust, J Wenger, D O'Connor, G W Griffith, B J Plant, M B Prentice

Open access · hybridAbstract read
In one paragraph

Article in The Journal of hospital infection, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Air pollution and COVID-19 severity.The European respiratory journal · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

M FennellySchool of Chemistry and Environmental Research Institute, University College Cork, Cork, Ireland; Department of Pathology, University College Cork, Cork, Ireland; School of Chemical and Pharmaceutical Sciences, Technological University Dublin, Dublin, Ireland. Electronic address: mehael.fennelly@tudublin.ie.
S HellebustSchool of Chemistry and Environmental Research Institute, University College Cork, Cork, Ireland.
J WengerSchool of Chemistry and Environmental Research Institute, University College Cork, Cork, Ireland.
D O'ConnorSchool of Chemical Sciences, Dublin City University, Dublin, Ireland.
G W GriffithDepartment of Life Sciences, Aberystwyth University, Aberystwyth, UK.
B J PlantAdult Cystic Fibrosis Centre, Cork University Hospital, University College Cork, Cork, Ireland.
M B PrenticeDepartment of Pathology, University College Cork, Cork, Ireland; APC Microbiome Institute, University College Cork, Cork, Ireland. Electronic address: m.prentice@ucc.ie.
University College Cork · IEAberystwyth University · GBDublin City University · IETechnological University Dublin · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As the severe acute respiratory syndrome coronavirus-2 pandemic has proceeded, ventilation has been recognized increasingly as an important tool in infection control. Many hospitals in Ireland and the UK do not have mechanical ventilation and depend on natural ventilation. The effectiveness of natural ventilation varies with atmospheric conditions and building design. In a challenge test of a legacy design ward, this study showed that portable air filtration significantly increased the clearance of pollutant aerosols of respirable size compared with natural ventilation, and reduced spatial variation in particle persistence. A combination of natural ventilation and portable air filtration is significantly more effective for particle clearance than either intervention alone.

Indexed as

Air Pollution, IndoorCOVID-19FiltrationHospitalsHumansInfection ControlRespiratory Aerosols and DropletsVentilationAirborneContinuous monitoringEnvironmentFiltrationHEPALow-cost sensors

Identifiers

PMID36198345
PMCPMC9526867
OpenAlexW4300003726

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials