ArticleMagnetic resonance in medicine2023
High-resolution dynamic susceptibility contrast perfusion imaging using higher-order temporal smoothness regularization.
Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Accurate actual flip angle imaging (AFI) in the presence of fat.Magnetic resonance in medicine · 2024Article
- High-resolution dynamic susceptibility contrast perfusion imaging using higher-order temporal smoothness regularization.Magnetic resonance in medicine · 2023Article
- Pharmacokinetic Analysis of Enhancement-Constrained Acceleration (ECA) reconstruction-based high temporal resolution breast DCE-MRI.PloS one · 2023Article
- Accelerated whole-brain perfusion imaging using a simultaneous multislice spin-echo and gradient-echo sequence with joint virtual coil reconstruction.Magnetic resonance in medicine · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeTo improve image quality and resolution of dynamic susceptibility contrast perfusion weighted imaging (DSC-PWI) by developing acquisition and reconstruction methods exploiting the temporal regularity property of DSC-PWI signal. THEORY AND
methodsA novel regularized reconstruction is proposed that recovers DSC-PWI series from interleaved segmented spiral k-space acquisition using higher order temporal smoothness (HOTS) properties of the DSC-PWI signal. The HOTS regularization is designed to tackle representational insufficiency of the standard first-order temporal regularizations for supporting higher accelerations. The higher accelerations allow for k-space coverage with shorter spiral interleaves resulting in improved acquisition point spread function, and acquisition of images at multiple TEs for more accurate DSC-PWI analysis.
resultsThe methods were evaluated in simulated and in-vivo studies. HOTS regularization provided increasingly more accurate models for DSC-PWI than the standard first-order methods with either quadratic or robust norms at the expense of increased noise. HOTS DSC-PWI optimized for noise and accuracy demonstrated significant advantages over both spiral DSC-PWI without temporal regularization and traditional echo-planar DSC-PWI, improving resolution and mitigating image artifacts associated with long readout, including blurring and geometric distortions. In context of multi-echo DSC-PWI, the novel methods allowed ∼4.3× decrease of voxel volume, providing 2× number of TEs compared to the previously published results.
conclusionsProposed HOTS reconstruction combined with dynamic spiral sampling represents a valid mechanism for improving image quality and resolution of DSC-PWI significantly beyond those available with established fast imaging techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials