Evidence map›Paper›PMID 36197491›Full record

ArticleArchives of orthopaedic and trauma surgery2023

Screw placement in arthroscopically assisted osteosynthesis of radial head fractures using a reference k-wire in the radiocapitellar joint: a cadaveric study.

Roland S Camenzind, Davide Cucchi, Tim Leschinger, Michael Hackl, Lars P Müller, Kilian Wegmann

Open access · hybridAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Roland S CamenzindCenter for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany. roland.camenzind@bluewin.ch.ORCID http://orcid.org/0000-0002-9096-2910
Davide CucchiDepartment of Orthopedic and Trauma Surgery, Cantonal Hospital Lucerne, Spitalstrasse, 6000, Lucerne, Switzerland.
Tim LeschingerCenter for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany.
Michael HacklDepartment of Orthopedic and Trauma Surgery, University Hospital Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany.
Lars P MüllerCenter for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany.
Kilian WegmannCenter for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany.
University of Cologne · DEUniversity Hospital Bonn · DEUniversity of Lucerne · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe optimal screw placement in arthroscopically assisted fixation of radial head fractures is still an issue and no guiding methods have been evaluated in the recent literature. The study hypothesis was that using a "reference k-wire" percutaneously inserted in and parallel to the radiocapitellar joint would enable to achieve a trajectory more parallel to the radial head articular surface as compared to a free-hand k-wire placement.

methodsArthroscopically assisted placement of a k-wire in the radial head was performed in seven fresh-frozen human cadaver specimens by three surgeons. Three different techniques were evaluated: freehand drilling (technique A), placement using a "reference" k-wire in the radiocapitellar joint as a reference without (technique B), and with the AO parallel k-wire guide (technique C). Radiographs from all procedures were obtained and the inclination angle "α" between the k-wire and the articular surface of the radial head was measured and compared among the techniques.

resultsAngles of 84 radiographs were obtained and showed a mean α angle of 30.1° ± 13° for technique A, 5.7° ± 4.5° for technique B, and 5.4° ± 3.7° for technique C. The angle α was significantly higher with technique A as compared to B (p < 0.0001) and C (p < 0.0001). There was no difference between methods B and C (n.s.). No difference was observed among the surgeons for all three methods (p = 0.66).

conclusionWith the use of an additional "reference" k-wire placed in the radiocapitellar joint, the guiding k-wire for screw drilling can be placed almost parallel to the radial head joint line with limited variability and a good reproducibility during arthroscopically assisted radial head fracture fixation. CLINICAL RELEVANCE: The here-presented method of an additional, percutaneous introduced "reference" k-wire is easily applicable and helpful to achieve parallel screw placement during arthroscopically assisted radial head fracture fixation. LEVEL OF EVIDENCE: IV, biomechanical cadaver study.

Indexed as

Elbow JointRadial Head and Neck FracturesRadius FracturesBone ScrewsBone WiresCadaverFracture Fixation, InternalHumansReproducibility of ResultsArthroscopic-assistedElbow arthroscopyRadial head fracturesReference k-wireScrew osteosynthesis

Identifiers

PMID36197491
PMCPMC10293376
OpenAlexW4301431172

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.