Evidence map›Paper›PMID 36196766›Full record

ArticleKorean journal of radiology2022

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction.

Chuluunbaatar Otgonbaatar, Jae-Kyun Ryu, Jaemin Shin, Ji Young Woo, Jung Wook Seo, Hackjoon Shim, Dae Hyun Hwang

Open access · hybridAbstract read
In one paragraph

Article in Korean journal of radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 31 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 6 institutions in 1 country.

Chuluunbaatar Otgonbaatar *Department of Radiology, College of Medicine, Seoul National University, Seoul, Korea.ORCID 0000-0002-8533-6165
Jae-Kyun Ryu *Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Korea.ORCID 0000-0003-1926-042X
Jaemin ShinDepartment of Radiology, Inje University Seoul Paik Hospital, Seoul, Korea.ORCID 0000-0001-6205-8222
Ji Young WooDepartment of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.ORCID 0000-0002-6200-0159
Jung Wook SeoDepartment of Radiology, Inje University Ilsan Paik Hospital, Goyang, Korea.ORCID 0000-0002-5975-8698
Hackjoon ShimMedical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Korea.ORCID 0000-0002-6731-0084
Dae Hyun HwangDepartment of Radiology, Inje University Seoul Paik Hospital, Seoul, Korea.ORCID 0000-0003-1995-6312
Hallym University Kangnam Sacred Heart Hospital · KRInje University Ilsan Paik Hospital · KRInje University Seoul Paik Hospital · KRSeoul Medical Center · KRSeoul National University · KRYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. MATERIALS AND

methodsCCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods.

resultsDLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (

conclusionDLR reconstruction provided better images than FBP and hybrid IR reconstruction.

Indexed as

Computed Tomography AngiographyDeep LearningAlgorithmsCoronary AngiographyCoronary VesselsHumansMaleRadiation DosageRadiographic Image Interpretation, Computer-AssistedStentsCoronary stentDeep learning reconstructionFiltered-back projectionHybrid iterative reconstructionValve apparatus

Identifiers

PMID36196766
PMCPMC9614292
OpenAlexW4302275539

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked