Evidence map›Paper›PMID 36196353›Full record

ArticleJournal of human kinetics2022

Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength.

António Carlos Sousa, Diogo Luís Marques, António Manuel Calado, Carlos Pacheco, Daniel Almeida Marinho, Mário Cardoso Marques, Bruno Filipe Travassos

Open access · diamondAbstract read
In one paragraph

Article in Journal of human kinetics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

António Carlos SousaDepartment of Sport Sciences, University of Beira Interior, Covilhã, Portugal.
Diogo Luís MarquesDepartment of Sport Sciences, University of Beira Interior, Covilhã, Portugal.
António Manuel CaladoRio Ave Rendimento, Rio Ave FC, Vila do Conde, Portugal.
Carlos PachecoRio Ave Rendimento, Rio Ave FC, Vila do Conde, Portugal.
Daniel Almeida MarinhoDepartment of Sport Sciences, University of Beira Interior, Covilhã, Portugal.
Mário Cardoso MarquesDepartment of Sport Sciences, University of Beira Interior, Covilhã, Portugal.
Bruno Filipe TravassosDepartment of Sport Sciences, University of Beira Interior, Covilhã, Portugal.
University of Beira Interior · PTNanium (Portugal) · PTSport Lisboa e Benfica · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength.

Indexed as

accuracygroinmeasurement errorportable dynamometersqueeze test

Identifiers

PMID36196353
PMCPMC9465726
OpenAlexW4224989535

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.