Evidence map›Paper›PMID 36195783›Full record

ArticleAnnals of biomedical engineering2023

Design, Analysis and Experimental Validation of a Novel 7-Degrees of Freedom Instrument for Laparoscopic Surgeries.

Prabhat Kumar, Sagar Talele, Suresh Deshpande, Rupesh Ghyar, Sritam Rout, Bhallamudi Ravi

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. A Hybrid Compliant-Tendon Laparoscopic Instrument for Distal Articulation and Grasping: Design and Experimental Validation.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026
    Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Prabhat KumarMechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
Sagar TaleleBETIC, Mechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
Suresh DeshpandeLaparoscopic Surgeon & Former President, IAGES, Swarup Hospital, Kolhapur, India.
Rupesh GhyarBETIC, Mechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India. rupesh.ghyar@betic.org.
Sritam RoutMechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
Bhallamudi RaviMechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
Indian Institute of Technology Bombay · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Laparoscopic surgery is widely used for treating intra-abdominal conditions involving the gallbladder, pancreas, liver, intestines and reproductive organs. Conventional laparoscopy instruments used in manual surgeries usually have straight shafts and four degrees of freedom (DOF) plus grasping. However, these are insufficient for the complete rotation of the instrument tip. This makes it challenging to access difficult-to-reach organs inside the abdomen during the surgeries. A few robotic instruments available in the market have higher maneuverability but are expensive. Instruments incorporating cable-based mechanisms require replacement after a few sterilization cycles. This paper describes a novel, reusable and affordable multi-DOF laparoscopy instrument that provides two additional DOF: (a) wrist articulation about one axis (wristed yaw) and (b) rotation of the jaw after articulation (jaw roll). The wrist can articulate up to 45° and also roll after articulation. The additional degrees of freedom enable better maneuverability, functionality and reach than conventional laparoscopy instruments. Further, the new instrument employs only rigid links, providing better strength and minimal loss of function after multiple sterilizations. The complete design of the novel instrument, followed by its kinematic analysis and force calculations are explained in this paper, concluding with its manufacture and experimental validation.

Indexed as

LaparoscopyRoboticsEquipment DesignLiverWristWrist JointDegree of FreedomKinematic analysisLaparoscopy instrument

Identifiers

PMID36195783
OpenAlexW4301185344

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.