Evidence map›Paper›PMID 36195519›Full record

ArticleZeitschrift fur medizinische Physik2023

Extension of the open-source TIGRE toolbox for proton imaging.

Stefanie Kaser, Thomas Bergauer, Ander Biguri, Wolfgang Birkfellner, Sepideh Hatamikia, Albert Hirtl, Christian Irmler, Benjamin Kirchmayer, Felix Ulrich-Pur

Open access · goldAbstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 3 countries.

Stefanie KaserInstitute of High Energy Physics, Austrian Academy of Sciences, Vienna, Austria. Electronic address: stefanie.kaser@oeaw.ac.at.
Thomas BergauerInstitute of High Energy Physics, Austrian Academy of Sciences, Vienna, Austria.
Ander BiguriDepartment of Applied Mathematics and Theoretical Physics (DAMTP), University of Cambridge, Cambridge, United Kingdom.
Wolfgang BirkfellnerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Sepideh HatamikiaAustrian Center for Medical Innovation and Technology, Wiener Neustadt, Austria; Research Center for Medical Image Analysis and Artificial Intelligence (MIAAI), Department of Medicine, Danube Private University, Krems, Austria; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Albert HirtlAtominstitut, TU Wien, Vienna, Austria.
Christian IrmlerInstitute of High Energy Physics, Austrian Academy of Sciences, Vienna, Austria.
Benjamin KirchmayerAtominstitut, TU Wien, Vienna, Austria.
Felix Ulrich-PurGSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany; Institute of High Energy Physics, Austrian Academy of Sciences, Vienna, Austria.
Austrian Academy of Sciences · ATMedical University of Vienna · ATTU Wien · ATGSI Helmholtz Centre for Heavy Ion Research · DEUniversity of Cambridge · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Proton irradiation is a well-established method to treat deep-seated tumors in radio oncology. Usually, an X-ray computed tomography (CT) scan is used for treatment planning. Since proton therapy is based on the precise knowledge of the stopping power describing the energy loss of protons in the patient tissues, the Hounsfield units of the planning CT have to be converted. This conversion introduces range errors in the treatment plan, which could be reduced, if the stopping power values were extracted directly from an image obtained using protons instead of X-rays. Since protons are affected by multiple Coulomb scattering, reconstruction of the 3D stopping power map results in limited image quality if the curved proton path is not considered. This work presents a substantial code extension of the open-source toolbox TIGRE for proton CT (pCT) image reconstruction based on proton radiographs including a curved proton path estimate. The code extension and the reconstruction algorithms are GPU-based, allowing to achieve reconstruction results within minutes. The performance of the pCT code extension was tested with Monte Carlo simulated data using three phantoms (Catphan® high resolution and sensitometry modules and a CIRS patient phantom). In the simulations, ideal and non-ideal conditions for a pCT setup were assumed. The obtained mean absolute percentage error was found to be below 1% and up to 8 lp/cm could be resolved using an idealized setup. These findings demonstrate that the presented code extension to the TIGRE toolbox offers the possibility for other research groups to use a fast and accurate open-source pCT reconstruction.

Indexed as

ProtonsProton TherapyAlgorithmsHumansImage Processing, Computer-AssistedMonte Carlo MethodPhantoms, ImagingRadiographyTomography, X-Ray ComputedProtonsGPU-based imagingIterative image reconstructionProton computed tomographyProton radiography

Identifiers

PMID36195519
PMCPMC10751710
OpenAlexW4298325760

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.