ArticleClinical ophthalmology (Auckland, N.Z.)2022
Impact of Global Optimization of Lens Constants on Absolute Prediction Error for Final IOL Power Selection When Using Intraoperative Aberrometry.
Article in Clinical ophthalmology (Auckland, N.Z.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Segmented Versus Global Optimization of Intraocular Lens Constants Across Axial Length: A Multi-Lens, Multi-Formula Comparison Using a Disjoint Training Dataset.Diagnostics (Basel, Switzerland) · 2026Article
- The Effect of Dry Eye Disease Treatment Prior to Cataract Surgery on Refractive Error Reduction.Journal of clinical medicine · 2026Article
- Comparative evaluation of several toric intraocular lens calculators for predicting postoperative refractive astigmatism in cataract surgery: a real-world study.BMC ophthalmology · 2025Article
- Multicenter Retrospective Analysis of Intraoperative Aberrometer Measurements and Associated Visual Outcomes with a Monofocal Aspheric Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Lens Factor Choice in IOL Power Calculation after Laser Refractive Surgery: The Right Constant for Advanced Lens Measurement Approach (ALMA).Journal of clinical medicine · 2024Article
- Refractive Prediction Accuracy Using Intraoperative Aberrometry versus Barrett True-K Formula Following Corneal Refractive Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Accuracy of the Majority Voting Method with Multiple IOL Power Formulae.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To evaluate absolute prediction errors following phacoemulsification with implantation of a multifocal toric intraocular lens (IOL) using intraoperative aberrometry for IOL power selection and to compare findings with the globally optimized and manufacturer's recommended lens constants and regression coefficients. Methods: Data from the Optiwave Refractive Analysis (ORA SYSTEM) were analyzed retrospectively. Absolute prediction errors from surgeries performed before and after the first optimization of the manufacturer's recommended lens constant and non-optimized regression coefficients for the multifocal toric IOL (SND1T3-6) were compared. Optimization was based on outcomes of procedures performed using the ORA SYSTEM and archived in its database (AnalyzOR). Outcome measures included the proportion of eyes with absolute ORA SYSTEM prediction errors ≤0.25 D and ≤0.5 D and the mean and median absolute prediction errors. Results: The pre-optimization group included 1027 eyes operated on by 184 surgeons, and the optimized group included 419 eyes operated on by 143 surgeons. The proportions of eyes achieving absolute ORA SYSTEM prediction errors ≤0.25 D (52.5% vs 35.0%, p < 0.0001) and ≤0.50 D (83.1% vs 66.2%, p < 0.0001) were significantly higher in the optimized than in the pre-optimization group. The mean ± standard deviation (0.30 ± 0.25 D vs 0.43 ± 0.32 D, p < 0.0001) and median (0.24 D vs 0.36 D, p < 0.0001) absolute ORA SYSTEM prediction errors were significantly lower after than before optimization. Prediction errors following optimization were reduced more in eyes of average than of long and short axial lengths. Conclusion: Global optimization of the manufacturer's IOL lens constants and regression coefficients resulted in lower absolute prediction errors when compared with the initial manufacturer labeled lens constants and non-optimized regression coefficients. Reductions in absolute prediction error can result in lower postoperative residual refractive error, which can improve post-operative uncorrected visual acuity and provide the potential for greater patient satisfaction following cataract surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.