Evidence map›Paper›PMID 36187933›Full record

ArticleEuropean heart journal. Case reports2022

Successful transvenous implantable cardioverter-defibrillator implantation supported by preceding 3D electro-anatomical mapping for a ventricular fibrillation survivor with surgically repaired congenitally corrected transposition of the great arteries: a case report.

Tadayuki Mitama, Tomoyuki Kabutoya, Kana Kubota Kashihara, Kazuomi Kario

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tadayuki MitamaDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, 3311-1, Yakushiji, Shimotsuke, Tochigi 329-0498, Japan.
Tomoyuki KabutoyaDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, 3311-1, Yakushiji, Shimotsuke, Tochigi 329-0498, Japan.ORCID https://orcid.org/0000-0002-5439-4303
Kana Kubota KashiharaDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, 3311-1, Yakushiji, Shimotsuke, Tochigi 329-0498, Japan.
Kazuomi KarioDivision of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, 3311-1, Yakushiji, Shimotsuke, Tochigi 329-0498, Japan.ORCID https://orcid.org/0000-0002-8251-4480

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The atrial sites suitable for lead placement are limited after complex surgical atrial procedures, and lead placement can be challenging in patients with congenitally corrected transposition of the great arteries (ccTGA) after intracardiac repair. Case summary: A 34-year-old man with ccTGA, who had undergone a double-switch operation with combined Senning and Jatene operations at the age of 14 was transferred to us. He experienced faintness and suffered cardiopulmonary arrest, and electrocardiography revealed ventricular fibrillation. After conversion to sinus rhythm by urgent external defibrillation, sinus bradycardia was revealed. Electrophysiological study was done using a three-dimensional (3D) mapping system (Ensite®) to evaluate the electrical condition of atria and to decide whether atrial lead can be transvenously placed. The electrical potential of the functional right atrium was good in the lateral or posterior wall, but the threshold was high. By contrast, the roof of the functional right atrium beyond cavoatrial junction was characterized by low voltage, but in a limited region of the roof of right atrium, the threshold was satisfactory and the electrical potential was normal. Thus, 3 weeks later, we implanted a transvenous implantable cardioverter-defibrillator (ICD). We used a 3D mapping system to place the atrial lead in the limited region of the roof of the right atrium mentioned above, the threshold was 0.7 V. Discussion: Electrophysiological examination using a 3D mapping system before implantation of a dual-chamber ICD is useful because atrial sites suitable for lead placement are limited in patients.

Indexed as

adult congenital heart diseasecase reportcongenitally corrected transposition of the great arterieselectrophysiological studyimplantable cardioverter-defibrillatorventricular fibrillation

Identifiers

PMID36187933
PMCPMC9518668

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.