Co-optimization method to improve lateral resolution in photoacoustic computed tomography.

Yang Zhang, Shufan Yang, Zhiying Xia, Ruijie Hou, Bin Xu, Lianping Hou, John H Marsh, Jamie Jiangmin Hou, Seyed Mojtaba Rezaei Sani, Xuefeng Liu and 1 more

Abstract read
In one paragraph

Article in Biomedical optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yang ZhangSchool of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.ORCID https://orcid.org/0000-0003-0290-7821
Shufan YangSchool of Computing, Edinburgh Napier University, Edinburgh, Scotland, EH10 5DT, UK.
Zhiying XiaSchool of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Ruijie HouSchool of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Bin XuSchool of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Lianping HouJames Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK.ORCID https://orcid.org/0000-0001-8405-8389
John H MarshJames Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK.ORCID https://orcid.org/0000-0002-2851-413X
Jamie Jiangmin HouThe Royal College of Surgeons of Edinburgh, Nicolson Street, Edinburgh, Scotland, EH8 9DW, UK.ORCID https://orcid.org/0000-0001-5836-1827
Seyed Mojtaba Rezaei SaniDepartment of Physics, North Tehran Branch, Islamic Azad University, Tehran 16511-53311, Iran.
Xuefeng LiuSchool of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Jichuan XiongSchool of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.ORCID https://orcid.org/0000-0002-7051-802X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In biomedical imaging, photoacoustic computed tomography (PACT) has recently gained increased interest as this imaging technique has good optical contrast and depth of acoustic penetration. However, a spinning blur will be introduced during the image reconstruction process due to the limited size of the ultrasonic transducers (UT) and a discontinuous measurement process. In this study, a damping UT and adaptive back-projection co-optimization (CODA) method is developed to improve the lateral spatial resolution of PACT. In our PACT system, a damping aperture UT controls the size of the receiving area, which suppresses image blur at the signal acquisition stage. Then, an innovative adaptive back-projection algorithm is developed, which corrects the undesirable artifacts. The proposed method was evaluated using agar phantom and ex-vivo experiments. The results show that the CODA method can effectively compensate for the spinning blur and eliminate unwanted artifacts in PACT. The proposed method can significantly improve the lateral spatial resolution and image quality of reconstructed images, making it more appealing for wider clinical applications of PACT as a novel, cost-effective modality.