Evidence map›Paper›PMID 36186085›Full record

ArticleIEEE journal of solid-state circuits2022

A Light-Tolerant Wireless Neural Recording IC for Motor Prediction With Near-Infrared-Based Power and Data Telemetry.

Jongyup Lim, Jungho Lee, Eunseong Moon, Michael Barrow, Gabriele Atzeni, Joseph G Letner, Joseph T Costello, Samuel R Nason, Paras R Patel, Yi Sun and 7 more

Open access · greenAbstract read
In one paragraph

Article in IEEE journal of solid-state circuits, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. A Sub-mmIEEE journal of solid-state circuits · 2024
    Article
  4. Article
  5. Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024
    Article
  6. Article
  7. A 0.43 g Wireless Battery-Less Neural Recorder With On-Chip Microelectrode Array and Integrated Flexible Antenna.IEEE microwave and wireless components letters : a publication of the IEEE Microwave Theory and Techniques Society · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors at 2 institutions in 1 country.

Jongyup LimDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Jungho LeeDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Eunseong MoonDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Michael BarrowDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Gabriele AtzeniDepartment of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland.
Joseph G LetnerDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Joseph T CostelloDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Samuel R NasonDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Paras R PatelDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Yi SunDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Parag G PatilDepartment of Neurological Surgery, Neurology, Anesthesiology, and Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Hun-Seok KimDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Cynthia A ChestekDepartment of Biomedical Engineering and Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, 48109 USA.
Jamie PhillipsDepartment of Electrical and Computer Engineering, University of Delaware, Newark, DE 19716 USA.
David BlaauwDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Dennis SylvesterDepartment of Electrical and Computer Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.
Taekwang JangDepartment of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland.
University of Michigan · USUniversity of Delaware · US

Funding

A 100μm Scale Single Unit Neural Recording Probe Using IR-Based Powering and CommunicationR21EY029452 · NEI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI BLAAUW, DAVID · 2018 to 2019
$430k
NEI NIH HHS R21 EY029452
6 · The paper itself

Abstract

Miniaturized and wireless near-infrared (NIR) based neural recorders with optical powering and data telemetry have been introduced as a promising approach for safe long-term monitoring with the smallest physical dimension among state-of-the-art standalone recorders. However, a main challenge for the NIR based neural recording ICs is to maintain robust operation in the presence of light-induced parasitic short circuit current from junction diodes. This is especially true when the signal currents are kept small to reduce power consumption. In this work, we present a light-tolerant and low-power neural recording IC for motor prediction that can fully function in up to 300

Indexed as

brain computer interfacebrain machine interfaceneural implantwireless neural recordingwireless sensor node

Identifiers

PMID36186085
PMCPMC9518712
OpenAlexW4206944723

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.