Evidence map›Paper›PMID 36185060›Full record

ArticleQuantitative imaging in medicine and surgery2022

Reproducibility of functional lung parameters derived from free-breathing non-contrast-enhanced 2D ultrashort echo-time.

Bingjie Yang, Patrick Metze, Anke Balasch, Kilian Stumpf, Meinrad Beer, Wolfgang Rottbauer, Volker Rasche

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bingjie YangDepartment of Internal Medicine II, Ulm University Medical Centre, Ulm, Germany.
Patrick MetzeDepartment of Internal Medicine II, Ulm University Medical Centre, Ulm, Germany.
Anke BalaschDepartment of Internal Medicine II, Ulm University Medical Centre, Ulm, Germany.
Kilian StumpfDepartment of Internal Medicine II, Ulm University Medical Centre, Ulm, Germany.
Meinrad BeerDepartment of Radiology, Ulm University Medical Centre, Ulm, Germany.
Wolfgang RottbauerDepartment of Internal Medicine II, Ulm University Medical Centre, Ulm, Germany.
Volker RascheDepartment of Internal Medicine II, Ulm University Medical Centre, Ulm, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Imaging the lung parenchyma with magnetic resonance imaging (MRI) is challenging due to cardiac and respiratory motion, the low proton density and short T Methods: In this study, a 2D UTE technique was combined with tiny golden angle (tyGA) ordering. Data were acquired either during breath-holds (BH) or continuously during free-breathing (FB) at a field strength of 3T. Retrospective self-gating (image- and k-space-based) was used to reconstruct respiratory and cardiac multistage images from the FB acquisitions. The reproducibility of functional lung parameters derived from BH and FB acquisitions was assessed for three independent examinations (M1-3). M1 and M2 were acquired within 2 h, whereas M3 was acquired at least 14 d after M1/2. Different respiratory and cardiac phases were reconstructed for three coronal slices. Quantitative analysis including proton fraction ( Results: All scans could be performed successfully in all volunteers. Intraclass correlation coefficients (ICC) of inter-measurement and inter-observer variability, and Bland-Altman analysis showed good to very good reproducibility. Larger breathing amplitudes were observed in the BH acquisitions, which also showed lower reproducibility when compared with the FB acquisitions. For the FB approach, the ICC ranged between 0.70 and 0.98 for all measurements, and ranged between 0.86 and 0.97 for the two observers. No bias or significant differences were observed between the three measurements or the two observers in healthy volunteers. Conclusions: The study proves the feasibility of FB 2D tyGA UTE for lung imaging. Functional parameters derived from FB acquisitions are reproducible in healthy volunteers, allowing for further investigation of this technique in patients with various underlying diseases.

Indexed as

fractional ventilation (FV)lung densityperfusionself-gatingUltrashort echo-time (UTE)

Identifiers

PMID36185060
PMCPMC9511423

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.