Evidence map›Paper›PMID 36182994›Full record

ArticleEJNMMI physics2022

Evaluation of a method based on synthetic data inserted into raw data prior to reconstruction for the assessment of PET scanners.

Quentin Maronnier, Frédéric Courbon, Olivier Caselles

Abstract read
In one paragraph

Article in EJNMMI physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Enhancing PET/CT target assessment with porous 3D printed grids: a pilot study.Physical and engineering sciences in medicine · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Quentin MaronnierMedical Physics Department, Institut Claudius Regaud, Toulouse, France. maronnier.quentin@iuct-oncopole.fr.ORCID http://orcid.org/0000-0002-2266-9122
Frédéric CourbonMedical Physics Department, Institut Claudius Regaud, Toulouse, France.
Olivier CasellesMedical Physics Department, Institut Claudius Regaud, Toulouse, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPerformance assessment of positron emission tomography (PET) scanners is crucial to guide clinical practice with efficiency. Even though clinical data are the final target, their use to characterize systems response is constrained by the lack of ground truth. Phantom tests overcome this limitation by controlling the object of study, but remain simple and are not representative of patient complexity. The objective of this study is to evaluate the accuracy of a simulation method using synthetic spheres inserted into acquired raw data prior to reconstruction, simulating multiple scenarios in comparison with equivalent physical experiments.

methodsWe defined our experimental framework using the National Electrical Manufacturers Association NU-2 2018 Image Quality standard, but replaced the standard sphere set with more appropriate sizes (4, 5, 6, 8, 10 and 13 mm) better suited to current PET scanner performance. Four experiments, with different spheres-to-background ratios (2:1, 4:1, 6:1 and 8:1), were performed. An additional dataset was acquired with a radioactive background but no activity within the spheres (water only) to establish a baseline. Then, we artificially simulated radioactive spheres to reproduce other experiments using synthetic data inserted into the original sinogram. Images were reconstructed following standard guidelines using ordered subset expectation maximization algorithm along with a Bayesian penalized likelihood algorithm. We first visually compared experimental and simulated images. Afterward, we measured the activity concentration values into the spheres to calculate the mean and maximum recovery coefficients (RC

resultsNo significant visual differences were identified between experimental and simulated series. Mann-Whitney U tests comparing simulated and experimental distributions showed no statistical differences for both RC

conclusionsWe evaluated the efficiency of our hybrid method in faithfully mimicking practical situations producing satisfactory results compared to equivalent experimental data.

Indexed as

ExperimentMethodsPerformancePhantomPositron emission tomographySimulation