Evidence map›Paper›PMID 36182927›Full record

ArticleChinese neurosurgical journal2022

Effects of Enterprise 2 stent-assisted coil embolization for wide-necked intracranial aneurysms.

Yangyang Zhou, Qichen Peng, Shiqing Mu

Open access · diamondAbstract read
In one paragraph

Article in Chinese neurosurgical journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Yangyang ZhouBeijing Neurosurgical Institute and Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China.
Qichen PengBeijing Neurosurgical Institute and Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China.
Shiqing MuBeijing Neurosurgical Institute and Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China. mu_sq1216@163.com.
Beijing Institute of Neurosurgery · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study analyzed the safety and efficacy of Enterprise 2 stent-assisted coil embolization for wide-necked intracranial aneurysms by examining stent-vessel apposition, operative complications, embolization outcomes, and clinical outcomes.

methodsWe retrospectively reviewed the medical records of patients with wide-necked intracranial aneurysms who underwent Enterprise 2 stent-assisted coiling in our hospital from November 2018 to October 2019. Intraoperative VasoCT was performed immediately after stent release in a continuous cohort of patients to observe stent-vessel apposition. Patient demographic, clinical, and imaging data were recorded and analyzed.

resultsA total of 106 wide-necked aneurysms in 106 patients were treated. Stent release was successful in all patients. Twenty-one patients were enrolled consecutively for VasoCT scanning, and incomplete stent apposition was observed in 5 (23.8%). Perioperative complications occurred in 10 patients (9.4%): cerebral infarction in 6, intraoperative coil prolapse in 1, puncture site pseudoaneurysm in 1, deep vein thrombosis at multiple sites in 1, and transient brainstem mass effect in 1. Among the 95 aneurysms with angiographic follow-up, embolization was satisfactory (Raymond-Roy classifications I and II) in 89 (93.7%). Hyperlipidemia was an independent risk factor for incomplete aneurysm occlusion. At the last clinical follow-up, seven patients had a poor clinical outcome (modified Rankin Scale score ≥ 3). Independent risk factors for poor outcomes were preoperative subarachnoid hemorrhage at presentation and cerebral infarction.

conclusionEnterprise 2 stent-assisted coiling for treatment of wide-necked intracranial aneurysms showed good safety and efficacy; however, incomplete stent apposition can still occur in vessels with a large curvature. Preoperative subarachnoid hemorrhage at presentation and cerebral infarction are the main reasons for poor clinical outcomes after stent-assisted coil embolization.

Indexed as

CoilingEnterprise 2 stentIntracranial aneurysmStent malpositionTreatment outcome

Identifiers

PMID36182927
PMCPMC9526926
OpenAlexW4298615988

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.