Metal implants on abdominal CT: does split-filter dual-energy CT provide additional value over iterative metal artifact reduction?

Hildegard M Wichtmann, Kai R Laukamp, Sebastian Manneck, Konrad Appelt, Bram Stieltjes, Daniel T Boll, Matthias R Benz, Markus M Obmann

Open access · hybridAbstract read
In one paragraph

Article in Abdominal radiology (New York), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 4 countries.

Hildegard M WichtmannClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland.ORCID 0000-0001-5561-2600
Kai R LaukampDepartment of Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
Sebastian ManneckClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland.
Konrad AppeltClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland.
Bram StieltjesClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland.
Daniel T BollClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland.
Matthias R BenzClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland.
Markus M ObmannClinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Petersgraben 4, CH-4031, Basel, Switzerland. Markus.Obmann@usb.ch.ORCID 0000-0001-6586-0034
University of Basel · CHUniversity Hospital Cologne · DEUniversity of California, Los Angeles · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess image quality and metal artifact reduction in split-filter dual-energy CT (sfDECT) of the abdomen with hip or spinal implants using virtual monoenergetic images (VMI) and iterative metal artifact reduction algorithm (iMAR).

methods102 portal-venous abdominal sfDECTs of patients with hip (n = 71) or spinal implants (n = 31) were included in this study. Images were reconstructed as 120kVp-equivalent images (Mixed) and VMI (40-190 keV), with and without iMAR. Quantitative artifact and image noise was measured using 12 different ROIs. Subjective image quality was rated by two readers using a five-point Likert-scale in six categories, including overall image quality and vascular contrast.

resultsLowest quantitative artifact in both hip and spinal implants was measured in VMI

conclusionFor abdominal sfDECT with hip or spinal implants Mixed

Indexed as

ArtifactsTomography, X-Ray ComputedAbdomenAlgorithmsHumansMetalsProstheses and ImplantsMetalsArthroplastyArtifactsDual-energy x-ray computed tomographyHipSpine

Identifiers

PMID36180598
PMCPMC9849167
OpenAlexW4298101463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.