Evidence map›Paper›PMID 36180520›Full record

ArticleScientific reports2022

Comparison of image registration methods for combining laparoscopic video and spectral image data.

Hannes Köhler, Annekatrin Pfahl, Yusef Moulla, Madeleine T Thomaßen, Marianne Maktabi, Ines Gockel, Thomas Neumuth, Andreas Melzer, Claire Chalopin

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hannes KöhlerInnovation Center Computer Assisted Surgery (ICCAS), Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany. hannes.koehler@medizin.uni-leipzig.de.
Annekatrin PfahlInnovation Center Computer Assisted Surgery (ICCAS), Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany.
Yusef MoullaDepartment of Visceral, Thoracic, Transplant, and Vascular Surgery, University Hospital of Leipzig, 04103, Leipzig, Germany.
Madeleine T ThomaßenDepartment of Visceral, Thoracic, Transplant, and Vascular Surgery, University Hospital of Leipzig, 04103, Leipzig, Germany.
Marianne MaktabiInnovation Center Computer Assisted Surgery (ICCAS), Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany.
Ines GockelDepartment of Visceral, Thoracic, Transplant, and Vascular Surgery, University Hospital of Leipzig, 04103, Leipzig, Germany.
Thomas NeumuthInnovation Center Computer Assisted Surgery (ICCAS), Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany.
Andreas MelzerInnovation Center Computer Assisted Surgery (ICCAS), Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany.
Claire ChalopinInnovation Center Computer Assisted Surgery (ICCAS), Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Laparoscopic procedures can be assisted by intraoperative modalities, such as quantitative perfusion imaging based on fluorescence or hyperspectral data. If these modalities are not available at video frame rate, fast image registration is needed for the visualization in augmented reality. Three feature-based algorithms and one pre-trained deep homography neural network (DH-NN) were tested for single and multi-homography estimation. Fine-tuning was used to bridge the domain gap of the DH-NN for non-rigid registration of laparoscopic images. The methods were validated on two datasets: an open-source record of 750 manually annotated laparoscopic images, presented in this work, and in-vivo data from a novel laparoscopic hyperspectral imaging system. All feature-based single homography methods outperformed the fine-tuned DH-NN in terms of reprojection error, Structural Similarity Index Measure, and processing time. The feature detector and descriptor ORB1000 enabled video-rate registration of laparoscopic images on standard hardware with submillimeter accuracy.

Indexed as

AlgorithmsLaparoscopyImage Processing, Computer-AssistedNeural Networks, Computer

Identifiers

PMID36180520
PMCPMC9525266

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.