Evidence map›Paper›PMID 36177845›Full record

ArticleOrthopaedic surgery2022

Effect of Hip Joint Center on Multi-body Dynamics and Contact Mechanics of Hip Arthroplasty for Crowe IV Dysplasia.

Yongchang Gao, Wei Chai, Zhicheng An, Xihui Chen, Zhe Dong, Zhifeng Zhang, Zhongmin Jin

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Yongchang GaoNational Engineering Laboratory for Highway Maintenance Equipment, Chang'an University, Xi'an, Shaanxi, China.ORCID https://orcid.org/0000-0002-7815-3790
Wei ChaiDepartment of Orthopaedics, The Chinese PLA General Hospital, Beijing, China.
Zhicheng AnNational Engineering Laboratory for Highway Maintenance Equipment, Chang'an University, Xi'an, Shaanxi, China.
Xihui ChenState Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Zhe DongNational Engineering Laboratory for Highway Maintenance Equipment, Chang'an University, Xi'an, Shaanxi, China.
Zhifeng ZhangState Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Zhongmin JinState Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Chang'an University · CNXi'an Jiaotong University · CNChinese PLA General Hospital · CN

Funding

National Natural Science Foundation of China 11902048National Natural Science Foundation of China 51805044National Natural Science Foundation of China 81772320Natural Science Foundation of Shaanxi Province of China 2020JM-253the National Natural Science Foundation of China 11902048the National Natural Science Foundation of China 51805044the National Natural Science Foundation of China 81772320the Natural Science Foundation of Shaanxi Province of China 2020JM-253
6 · The paper itself

Abstract

objectiveTo investigate the hip joint forces, Von Mises stress, contact pressure and micro-motion of hip prosthesis for developmental dysplasia of the hip (DDH) patients under different hip joint centers using musculoskeletal (MSK) multi-body dynamics and finite element analysis.

methodsBoth MSK multi-body dynamics model and finite element (FE) model were based on CT data of a young female DDH patient with total hip replacement and were developed to study the biomechanics of the S-ROM hip prosthesis. The same offset of hip joint center along all six orientations compared with the standard position was set to predict its effects on both MSK multi-body dynamics and contact mechanics during one gait cycle.

resultsThe hip joint forces in the entire walking gait cycle showed two peak values and clear differences between them under different hip joint centers. The hip joint force increased when the hip joint center moved posteriorly (2101 N) and laterally (1969 N) to the anatomical center (1848 N) at the first peak by 13.7% and 6.6%, respectively. The hip joint force increased sharply when the hip center deviated laterally (2115 N) and anteriorly (2407 N), respectively, from the standard position (1742 N) at the second peak. For the sleeve of the S-ROM prosthesis, the maximum Von Mises stress and contact pressure of the sleeve increased if the hip joint center deviated from the anatomical center posteriorly at the first peak. However, the Von Mises stresses and contact pressure increased at anterior and lateral orientations, compared to that of the standard position at the second peak. Small changes were observed for the maximum relative sliding distance along most of the orientations at both peaks except in the lateral and medial orientations, in which an increase of 8.6% and a decrease of 13.6% were observed, respectively.

conclusionThe hip joint center obviously influenced the hip joint forces, stress, contact pressure and micro-motion of the hip implant for this female patient.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisBiomechanical PhenomenaFemaleFinite Element AnalysisGaitHip JointHumansContact mechanicsDevelopmental dysplasia of the hipFinite element analysisMusculoskeletal multi-body dynamicsTotal hip replacement

Identifiers

PMID36177845
PMCPMC9627082
OpenAlexW4298087338

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.