Evidence map›Paper›PMID 36175915›Full record

ArticleJournal of orthopaedic surgery and research2022

Patient-specific three-dimensional evaluation of interface micromotion in two different short stem designs in cementless total hip arthroplasty: a finite element analysis.

Arata Kanaizumi, Daisuke Suzuki, Satoshi Nagoya, Atsushi Teramoto, Toshihiko Yamashita

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Arata KanaizumiDepartment of Orthopaedic Surgery, School of Medicine, Sapporo Medical University, 291, Minami 1 Jo Nishi 16 Chome, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan. a.kanaizumi@sapmed.ac.jp.
Daisuke SuzukiFaculty of Health Science, Hokkaido Chitose College of Rehabilitation, 2-10-10 Satomi, Chitose, Hokkaido, 066-0055, Japan.
Satoshi NagoyaDepartment of Musculoskeletal Biomechanics and Surgical Development, Sapporo Medical University, Minami 1 Jo Nishi 17 Chome, Chuo-ku, Sapporo, Hokkaido, 060-8556, Japan.
Atsushi TeramotoDepartment of Orthopaedic Surgery, School of Medicine, Sapporo Medical University, 291, Minami 1 Jo Nishi 16 Chome, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan.
Toshihiko YamashitaDepartment of Orthopaedic Surgery, School of Medicine, Sapporo Medical University, 291, Minami 1 Jo Nishi 16 Chome, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan.
Sapporo Medical University · JPHokkaido Chitose College of Rehabilitation · JP

Funding

Japan Society for the Promotion of Science JP21K09254
6 · The paper itself

Abstract

backgroundEvaluation of micromotion in various activities in daily life is essential to the assessment of the initial fixation of cementless short stems in total hip arthroplasty. This study sought to evaluate three-dimensionally the micromotion of two types of cementless short stems.

methodsTwo types of stems were used: the Fitmore stem with a rectangular cross-section (rectangular stem) and the octagonal-oval GTS stem with fins (finned stem). Finite element analysis was used to calculate the micromotion of two activities that place a heavy load on the stem (single-leg stance and stair climbing). Three values were measured: the magnitude of micromotion (mean and 95th percentile), the location of micromotion above the 95th percentile value, and the directions of the micromotion vector.

results1. There was no significant difference in the magnitude of the micromotion between the rectangular stem and finned stem groups for single-leg stance or stair climbing. 2. In both groups, the micromotion was greatest at the proximal and distal ends. 3. The direction of the micromotion was similar in both groups; internal rotation occurred from the distal to the middle of the stem during stair climbing.

conclusionsThe rectangular stem had comparable initial fixation to that of the finned stem. In both models, the micromotion was greater at the proximal and distal ends. The direction of the micromotion was not dependent on the stem shape but on the direction of the load on the artificial femoral head. These results will be important for stem selection and future stem development.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisFemurFemur HeadFinite Element AnalysisHumansProsthesis DesignCementless short stemFinite element analysisMicromotionTotal hip arthroplastyVector

Identifiers

PMID36175915
PMCPMC9524017
OpenAlexW4297963109

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.