Evidence map›Paper›PMID 36173393›Full record

ArticleJournal of the American Society for Mass Spectrometry2022

Next-Generation Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Source for Mass Spectrometry Imaging and High-Throughput Screening.

Kevan T Knizner, Jacob P Guymon, Kenneth P Garrard, Guy Bouvrée, Jeffrey Manni, Jan-Peter Hauschild, Kerstin Strupat, Kyle L Fort, Lee Earley, Eloy R Wouters and 6 more

Open access · greenAbstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
4.4field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Feasibility of IR-MALDESI Mass Spectrometry Imaging of PFAS.Journal of mass spectrometry : JMS · 2025
    Article
  17. Article
  18. Article
  19. Article
  20. Oversampling for Enhanced Spatial Resolution of Zebrafish by Top-Hat IR-MALDESI-MSI.Journal of the American Society for Mass Spectrometry · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 4 institutions in 2 countries.

Kevan T KniznerFTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.
Jacob P GuymonPrecision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States.
Kenneth P GarrardFTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.
Guy BouvréeGB Conseil & Services, 77170 Brie Comte Robert, France.
Jeffrey ManniJGM Associates, Inc., Burlington, Massachusetts 01803, United States.
Jan-Peter HauschildThermo Fisher Scientific (Bremen) GmbH, 28199 Bremen, Germany.
Kerstin StrupatThermo Fisher Scientific (Bremen) GmbH, 28199 Bremen, Germany.
Kyle L FortThermo Fisher Scientific (Bremen) GmbH, 28199 Bremen, Germany.
Lee EarleyThermo Fisher Scientific, San Jose, California 95134, United States.
Eloy R WoutersThermo Fisher Scientific, San Jose, California 95134, United States.
Fan PuDrug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States.
Andrew J RadosevichDrug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States.ORCID 0000-0003-4435-6749
Nathaniel L ElsenDrug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States.ORCID 0000-0003-1192-7242
Jon D WilliamsDrug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States.ORCID 0000-0001-9873-4165
Mark R PankowPrecision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States.
David C MuddimanFTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.ORCID 0000-0003-2216-499X
North Carolina State University · USAbbVie (United States) · USThermo Fisher Scientific (Germany) · DEThermo Fisher Scientific (United States) · US

Funding

Development and Application of New Ionization Methods for Biological Mass SpectrometryR01GM087964 · NIGMS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI MUDDIMAN, DAVID C. · 2010 to 2025
$4.7M
NIGMS NIH HHS R01 GM087964
6 · The paper itself

Abstract

Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid, ambient ionization source that combines the advantages of electrospray ionization and matrix-assisted laser desorption/ionization, making it a versatile tool for both high-throughput screening (HTS) and mass spectrometry imaging (MSI) studies. To expand the capabilities of the IR-MALDESI source, an entirely new architecture was designed to overcome the key limitations of the previous source. This next-generation (NextGen) IR-MALDESI source features a vertically mounted IR-laser, a planar translation stage with computerized sample height control, an aluminum enclosure, and a novel mass spectrometer interface plate. The NextGen IR-MALDESI source has improved user-friendliness, improved overall versatility, and can be coupled to numerous Orbitrap mass spectrometers to accommodate more research laboratories. In this work, we highlight the benefits of the NextGen IR-MALDESI source as an improved platform for MSI and direct analysis. We also optimize the NextGen MALDESI source component geometries to increase target ion abundances over a wide

Indexed as

High-Throughput Screening AssaysSpectrometry, Mass, Electrospray IonizationLasersSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationDesign of ExperimentsHigh-Throughput ScreeningIR-MALDESIMass Spectrometry ImagingOrbitrap Mass Spectrometer

Identifiers

PMID36173393
PMCPMC9944128
OpenAlexW4297965280

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.