Evidence map›Paper›PMID 36171424›Full record

ArticleScientific reports2022

Flexible ultrasound transceiver array for non-invasive surface-conformable imaging enabled by geometric phase correction.

Jeffrey Elloian, Jakub Jadwiszczak, Volkan Arslan, Jeffrey D Sherman, David O Kessler, Kenneth L Shepard

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Article
  3. A Conformable CMOS Ultrasound System for Point-of-Care Imaging.medRxiv : the preprint server for health sciences · 2026
    Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. UltraFlex: Iterative Model-Based Ultrasonic Flexible-Array Shape Calibration.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  9. Article
  10. Article
  11. Emerging Wearable Ultrasound Technology.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Review
  12. Clinical, Safety, and Engineering Perspectives on Wearable Ultrasound Technology: A Review.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jeffrey Elloian *Department of Electrical Engineering, Columbia University, 500 W 120th St., New York, NY, 10027, USA.
Jakub Jadwiszczak *Department of Electrical Engineering, Columbia University, 500 W 120th St., New York, NY, 10027, USA.
Volkan ArslanDepartment of Electrical Engineering, Columbia University, 500 W 120th St., New York, NY, 10027, USA.
Jeffrey D ShermanDepartment of Electrical Engineering, Columbia University, 500 W 120th St., New York, NY, 10027, USA.
David O KesslerDepartment of Emergency Medicine, Morgan Stanley Children's Hospital of New York Presbyterian at Columbia University Medical Center, New York, 10032, USA.
Kenneth L ShepardDepartment of Electrical Engineering, Columbia University, 500 W 120th St., New York, NY, 10027, USA. shepard@ee.columbia.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultrasound imaging provides the means for non-invasive real-time diagnostics of the internal structure of soft tissue in living organisms. However, the majority of commercially available ultrasonic transducers have rigid interfaces which cannot conform to highly-curved surfaces. These geometric limitations can introduce a signal-quenching air gap for certain topographies, rendering accurate imaging difficult or impractical. Here, we demonstrate a 256-element flexible two-dimensional (2D) ultrasound piezoelectric transducer array with geometric phase correction. We show surface-conformable real-time B-mode imaging, down to an extreme radius of curvature of 1.5 cm, while maintaining desirable performance metrics such as high signal-to-noise ratio (SNR) and minimal elemental cross-talk at all stages of bending. We benchmark the array capabilities by resolving reflectors buried at known locations in a medical-grade tissue phantom, and demonstrate how phase correction can improve image reconstruction on curved surfaces. With the current array design, we achieve an axial resolution of ≈ 2 mm at clinically-relevant depths in tissue, while operating the array at 1.4 MHz with a bandwidth of ≈ 41%. We use our prototype to image the surface of the human humerus at different positions along the arm, demonstrating proof-of-concept applicability for real-time diagnostics using phase-corrected flexible ultrasound probes.

Indexed as

Diagnostic ImagingTransducersEquipment DesignHumansPhantoms, ImagingUltrasonography

Identifiers

PMID36171424
PMCPMC9519534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.