Evidence map›Paper›PMID 36168935›Full record

ArticleJournal of applied clinical medical physics2022

Development of an unsupervised cycle contrastive unpaired translation network for MRI-to-CT synthesis.

Jiangtao Wang, Bing Yan, Xinhong Wu, Xiao Jiang, Yang Zuo, Yidong Yang

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiangtao WangDepartment of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China.
Bing YanDepartment of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China.
Xinhong WuDepartment of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China.
Xiao JiangDepartment of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China.
Yang ZuoDepartment of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China.
Yidong YangDepartment of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this work is to develop and evaluate a novel cycle-contrastive unpaired translation network (cycleCUT) for synthetic computed tomography (sCT) generation from T1-weighted magnetic resonance images (MRI).

methodsThe cycleCUT proposed in this work integrated the contrastive learning module from contrastive unpaired translation network (CUT) into the cycle-consistent generative adversarial network (cycleGAN) framework to effectively achieve unsupervised CT synthesis from MRI. The diagnostic MRI and radiotherapy planning CT images of 24 brain cancer patients were obtained and reshuffled to train the network. For comparison, the traditional cycleGAN and CUT were also implemented. The sCT images were then imported into a treatment planning system to verify their feasibility for radiotherapy planning. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) between the sCT and the corresponding real CT images were calculated. Gamma analysis between sCT- and CT-based dose distributions was also conducted.

resultsQuantitative evaluation of an independent test set of six patients showed that the average MAE was 69.62 ± 5.68 Hounsfield Units (HU) for the proposed cycleCUT, significantly (p-value < 0.05) lower than that for cycleGAN (77.02 ± 6.00 HU) and CUT (78.05 ± 8.29). The average PSNR was 28.73 ± 0.46 decibels (dB) for cycleCUT, significantly larger than that for cycleGAN (27.96 ± 0.49 dB) and CUT (27.95 ± 0.69 dB). The average SSIM for cycleCUT (0.918 ± 0.012) was also significantly higher than that for cycleGAN (0.906 ± 0.012) and CUT (0.903 ± 0.015). Regarding gamma analysis, cycleCUT achieved the highest passing rate (97.95 ± 1.24% at the 2%/2 mm criteria and 10% dose threshold) but was not significantly different from the others.

conclusionThe proposed cycleCUT could be effectively trained using unaligned image data, and could generate better sCT images than cycleGAN and CUT in terms of HU number accuracy and fine structural details.

Indexed as

Brain NeoplasmsRadiotherapy Planning, Computer-AssistedHumansMagnetic Resonance ImagingSignal-To-Noise RatioTomography, X-Ray Computedcontrastive unpaired translation networkcycle-consistent generative adversarial networkMRI-only workflowsynthetic CT

Identifiers

PMID36168935
PMCPMC9680583

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.