ArticleJournal of applied clinical medical physics2022
Development of an unsupervised cycle contrastive unpaired translation network for MRI-to-CT synthesis.
Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Clinical implementation of deep learning-based synthetic CT for MRI-only volumetric modulated arc therapy in head and neck and pelvic cancer patients.Radiation oncology (London, England) · 2025Article
- Synthetic polarization-sensitive optical coherence tomography using contrastive unpaired translation.Scientific reports · 2024Article
- CT synthesis with deep learning for MR-only radiotherapy planning: a review.Biomedical engineering letters · 2024Review
- Proton dose calculation on cone-beam computed tomography using unsupervised 3D deep learning networks.Physics and imaging in radiation oncology · 2024Article
- Channel-wise attention enhanced and structural similarity constrained cycleGAN for effective synthetic CT generation from head and neck MRI images.Radiation oncology (London, England) · 2024Article
- Machine Learning for Medical Image Translation: A Systematic Review.Bioengineering (Basel, Switzerland) · 2023Review
- Development of an unsupervised cycle contrastive unpaired translation network for MRI-to-CT synthesis.Journal of applied clinical medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this work is to develop and evaluate a novel cycle-contrastive unpaired translation network (cycleCUT) for synthetic computed tomography (sCT) generation from T1-weighted magnetic resonance images (MRI).
methodsThe cycleCUT proposed in this work integrated the contrastive learning module from contrastive unpaired translation network (CUT) into the cycle-consistent generative adversarial network (cycleGAN) framework to effectively achieve unsupervised CT synthesis from MRI. The diagnostic MRI and radiotherapy planning CT images of 24 brain cancer patients were obtained and reshuffled to train the network. For comparison, the traditional cycleGAN and CUT were also implemented. The sCT images were then imported into a treatment planning system to verify their feasibility for radiotherapy planning. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) between the sCT and the corresponding real CT images were calculated. Gamma analysis between sCT- and CT-based dose distributions was also conducted.
resultsQuantitative evaluation of an independent test set of six patients showed that the average MAE was 69.62 ± 5.68 Hounsfield Units (HU) for the proposed cycleCUT, significantly (p-value < 0.05) lower than that for cycleGAN (77.02 ± 6.00 HU) and CUT (78.05 ± 8.29). The average PSNR was 28.73 ± 0.46 decibels (dB) for cycleCUT, significantly larger than that for cycleGAN (27.96 ± 0.49 dB) and CUT (27.95 ± 0.69 dB). The average SSIM for cycleCUT (0.918 ± 0.012) was also significantly higher than that for cycleGAN (0.906 ± 0.012) and CUT (0.903 ± 0.015). Regarding gamma analysis, cycleCUT achieved the highest passing rate (97.95 ± 1.24% at the 2%/2 mm criteria and 10% dose threshold) but was not significantly different from the others.
conclusionThe proposed cycleCUT could be effectively trained using unaligned image data, and could generate better sCT images than cycleGAN and CUT in terms of HU number accuracy and fine structural details.