Evidence map›Paper›PMID 36167889›Full record

ArticleAnnals of nuclear medicine2022

Attenuation correction for phantom tests: an alternative to maximum-likelihood attenuation correction factor-based correction for clinical studies in time-of-flight PET.

Tetsuro Mizuta, Yoshiyuki Yamakawa, Suzuka Minagawa, Tetsuya Kobayashi, Atsushi Ohtani, Shiho Takenouchi, Kohei Hanaoka, Shota Watanabe, Daisuke Morimoto-Ishikawa, Takahiro Yamada and 2 more

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of nuclear medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Off-target binding ofAnnals of nuclear medicine · 2026
    Article
  2. Impact ofEJNMMI physics · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Tetsuro MizutaMedical Systems Division, Shimadzu Corporation, 1, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511, Japan. mizuta@shimadzu.co.jp.
Yoshiyuki YamakawaMedical Systems Division, Shimadzu Corporation, 1, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511, Japan.
Suzuka MinagawaMedical Systems Division, Shimadzu Corporation, 1, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511, Japan.
Tetsuya KobayashiTechnology Research Laboratory, Shimadzu Corporation, Kyoto, Japan.
Atsushi OhtaniMedical Systems Division, Shimadzu Corporation, 1, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511, Japan.
Shiho TakenouchiMedical Systems Division, Shimadzu Corporation, 1, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511, Japan.
Kohei HanaokaDivision of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University, Osakasayama, Japan.
Shota WatanabeDivision of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University, Osakasayama, Japan.
Daisuke Morimoto-IshikawaDivision of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University, Osakasayama, Japan.
Takahiro YamadaDivision of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University, Osakasayama, Japan.
Hayato KaidaDivision of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University, Osakasayama, Japan.
Kazunari IshiiDivision of Positron Emission Tomography, Institute of Advanced Clinical Medicine, Kindai University, Osakasayama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study evaluates the phantom attenuation correction (PAC) method as an alternative to maximum-likelihood attenuation correction factor (ML-ACF) correction in time-of-flight (TOF) brain positron emission tomography (PET) studies.

methodsIn the PAC algorithm, a template emission image [Formula: see text] and a template attenuation coefficient image [Formula: see text] are prepared as a data set based on phantom geometry. Position-aligned attenuation coefficient image [Formula: see text] is derived by aligning [Formula: see text] using parameters that match the template emission image [Formula: see text] to measured emission image [Formula: see text]. Then, attenuation coefficient image [Formula: see text] combined with a headrest image is used for scatter and attenuation correction in the image reconstruction. To evaluate the PAC algorithm as an alternative to ML-ACF, Hoffman 3D brain and cylindrical phantoms were measured to obtain the image quality indexes of contrast and uniformity. These phantoms were also wrapped with a radioactive sheet to obtain attenuation coefficient images using ML-ACF. Emission images were reconstructed with attenuation correction by PAC and ML-ACF, and the results were compared using contrast and uniformity as well as visual assessment. CT attenuation correction (CT-AC) was also applied as a reference.

resultsThe contrast obtained by ML-ACF was slightly overestimated due to its unique experimental condition for applying ML-ACF in Hoffman 3D brain phantom but the uniformity was almost equivalent among ML-ACF, CT-AC, and PAC. PAC showed reasonable result without overestimation compared to ML-ACF and CT-AC.

conclusionsPAC is an attenuation correction method that can ensure the performance in phantom test, and is considered to be a reasonable alternative to clinically used ML-ACF-based attenuation correction.

Indexed as

Image Processing, Computer-AssistedPositron-Emission TomographyAlgorithmsBrainHumansMagnetic Resonance ImagingPhantoms, ImagingAttenuation correctionML-ACFPETPhantom criteria

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.