Evidence map›Paper›PMID 36167535›Full record

ArticleBMC medical imaging2022

Quantitative evaluation of aortic valve regurgitation in 4D flow cardiac magnetic resonance: at which level should we measure?

Malgorzata Polacin, Julia Geiger, Barbara Burkhardt, Fraser M Callaghan, Emanuela Valsangiacomo, Christian Kellenberger

Abstract read
In one paragraph

Article in BMC medical imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Malgorzata PolacinInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland. Malgorzata.Polacin@usz.ch.
Julia GeigerDepartment of Diagnostic Imaging, University Children`s Hospital, University of Zurich, Zurich, Switzerland.
Barbara BurkhardtDivision of Pediatric Cardiology, Pediatric Heart Center, University Children`s Hospital, University of Zurich, Zurich, Switzerland.
Fraser M CallaghanCenter for MR Research, University Children's Hospital, University of Zurich, Zurich, Switzerland.
Emanuela ValsangiacomoDivision of Pediatric Cardiology, Pediatric Heart Center, University Children`s Hospital, University of Zurich, Zurich, Switzerland.
Christian KellenbergerDepartment of Diagnostic Imaging, University Children`s Hospital, University of Zurich, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR.

methodsIn 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach.

resultsAfter assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1-2 than at levels 3-6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1-2 were lower compared to levels 3-6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986-0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943-0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 - 0.998) was best at the level of PA.

conclusionFor estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.

Indexed as

Aortic Valve InsufficiencyAortic ValveFemaleHumansMagnetic Resonance Imaging, CineMagnetic Resonance SpectroscopyMaleReproducibility of ResultsSeverity of Illness Index4D flowAortic regurgitationCardiac magnetic resonance

Identifiers

PMID36167535
PMCPMC9513957

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.