ArticlePrecision radiation oncology2022
A Review of Proton Therapy - Current Status and Future Directions.
Article in Precision radiation oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 105 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
105 citing papers in PubMed, 2 syntheses or guidelines pooled it, 206 citations in OpenAlex.
- Evaluating the Effectiveness of Proton Beam Therapy Compared to Conventional Radiotherapy in Non-Metastatic Rectal Cancer: A Systematic Review of Clinical Outcomes.Medicina (Kaunas, Lithuania) · 2024Pooled it
- Health Economic Evaluation of Proton Therapy for Lung Cancer: A Systematic Review.International journal of environmental research and public health · 2023Pooled it
- Ultrastructural pathological features and clinical significance of recurrent chordoma.Journal of bone oncology · 2026Article
- Physician- and Patient-Reported Outcomes Following Contemporary Image Guided Intensity Modulated Proton Therapy for Prostate Cancer: Results From the Prospective PRO-Cube Study.Advances in radiation oncology · 2026Article
- A two-stage framework for fast proton spot map generation in pencil beam scanning prostate SBRT planning.Medical physics · 2026Article
- Review
- Artificial Intelligence in Particle Therapy Treatment Planning: Current Advances and Future Directions.International journal of particle therapy · 2026Article
- Causal Machine Learning Analysis of Empirical Relative Biological Effectiveness for Mandible Osteoradionecrosis in Head and Neck Cancer Radiation Therapy.International journal of radiation oncology, biology, physics · 2026Article
- Effects of materials and beam currents on ozone generation in proton beam irradiation: a phantom study.Journal of radiation research · 2026Article
- Nonlinear Redox-Immune Coupling Under Low-Dose-Rate Radiation: A Compartment-Specific Framework for Biological Responses-A Narrative Review.Antioxidants (Basel, Switzerland) · 2026Review
- Mechanobiology of the tumor microenvironment: a review of therapeutic interactions and in vitro elasticity measurement techniques.Journal of biomedical science · 2026Review
- Significant aggravation of pre-existing myalgic encephalomyelitis/chronic fatigue syndrome following proton beam therapy for sphenoid wing meningioma: case report.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026Article
- Characterization of a Low-Energy Cyclotron-Based Proton Beam for Preclinical Radiobiological Studies.International journal of particle therapy · 2026Article
- Three-Discipline Collaborative Radiation Therapy (3DCRT) debate: Medical physics should focus less on geometric precision and more on biological outcomes.Journal of applied clinical medical physics · 2026Article
- Ionizing radiation acoustic beam localization: one step towards "proton surgery".medRxiv : the preprint server for health sciences · 2026Article
- A Monte Carlo study of proton LET calculations: Comparison between the codes PENHAN, FLUKA, and TOPAS.Medical physics · 2026Article
- Knowledge based automated planning for non-coplanar VMAT stereotactic radiosurgery in ocular malignancies.Journal of applied clinical medical physics · 2026Article
- Recent advancements in radiotherapy for hepatocellular carcinoma.ESMO gastrointestinal oncology · 2026Review
- Trends and Challenges: A 15-Year Review of Imaging and Radiation Oncology Core Anthropomorphic Phantom Audits for Proton Therapy.International journal of particle therapy · 2026Article
- Review
45 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
The original rationale for proton therapy was the highly conformal depth-dose distributions that protons are able to produce, compared to photons, which allow greater sparing of normal tissues and escalation of tumor doses, thus potentially improving outcomes. Additionally, recent research, which is still ongoing, has revealed previously unrecognized advantages of proton therapy. For instance, the higher relative biological effectiveness (RBE) near the end of the proton range can be exploited to increase the difference in biologically effective dose in tumors vs. normal tissues. Moreover, the smaller "dose bath", i.e., the compact nature of proton dose distributions has been found to reduce exposure of circulating lymphocytes and the immune organs at risk. There is emerging evidence that the resulting sparing of the immune system has the potential to improve outcomes. Protons, accelerated to therapeutic energies ranging from 70 to 250 MeV, are transported to the treatment room where they enter the treatment head mounted on a rotating gantry. The initially narrow beams of protons are spread laterally and longitudinally and shaped appropriately to deliver treatments. Spreading and shaping can be achieved by electro-mechanically for "passively-scattered proton therapy' (PSPT); or using magnetic scanning of thin "beamlets" of protons of a sequence of initial energies. The latter technique is used to treat patients with optimized intensity modulated proton therapy (IMPT), the most powerful proton therapy modality, which is rapidly supplanting PSPT. Treatment planning and plan evaluation for proton therapy require different techniques compared to photon therapy due, in part, to the greater vulnerability of protons to uncertainties, especially those introduced by inter- and intra-fractional variations in anatomy. In addition to anatomic variations, other sources of uncertainty in the treatments delivered include the approximations and assumptions of models used for computing dose distributions and the current practice of proton therapy of assuming the RBE to have a constant value of 1.1. In reality, the RBE is variable and a complex function of proton energy, dose per fraction, tissue and cell type, end point, etc. Despite the high theoretical potential of proton therapy, the clinical evidence supporting its broad use has so far been mixed. The uncertainties and approximations mentioned above, and the technological limitations of proton therapy may have diminished its true clinical potential. It is generally acknowledged that proton therapy is safe, effective and recommended for many types of pediatric cancers, ocular melanomas, chordomas and chondrosarcomas. Promising results have been and continue to be reported for many other types of cancers as well; however, they are based on small studies. At the same time, there have been reports of unforeseen toxicities. Furthermore, because of the high cost of establishing and operating proton therapy centers, questions are often raised about the value of proton therapy. The general consensus is that there is a need for continued improvement in the state of the art of proton therapy. There is also a need to conduct randomized trials and/or collect outcomes data in multi-institutional registries to generate high level evidence of the advantages of protons. Fortuitously, such efforts are taking currently place. Ongoing research is aimed at better understanding the biological and immunomodulatory effects of proton therapy and the consequences of the physical uncertainties on proton therapy and reducing them through image-guidance and adaptive radiotherapy. Since residual uncertainties will remain despite our best efforts, in order to increase the resilience of dose distributions in the face of uncertainties and improve our confidence in dose distributions seen on treatment plans, robust optimization techniques are being developed and implemented and continue to be perfected. Such research and continuing technological advancements in planning and delivery methods are likely to help demonstrate the superiority of protons.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.