ArticleWorld journal of orthopedics2022
Quantitative alpha-defensin testing: Is synovial fluid dilution important?
Article in World journal of orthopedics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Diagnostic accuracy of alpha-defensin ELISA and lateral flow assays for periprosthetic joint infection: a systematic review and meta-analysis.Journal of bone and joint infection · 2025Review
- Analysis of Serum and Synovial Inflammatory Markers in Periprosthetic Joint Infections: A Narrative Review.Cureus · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAlpha-defensin has been widely studied for the diagnosis of periprosthetic joint infection (PJI). However, there is a lack of detailed information regarding the proper laboratory technique of the enzyme-linked immunosorbent assay (ELISA) method, such as sample dilution.
aimTo assess the influence of dilution in the synovial fluid during ELISA for the diagnosis of knee PJI; and determine which dilution presents a better performance.
methodsForty samples of synovial fluid from arthroplasty knees were included, 17 in the infected group and 23 in the aseptic group, according to Musculoskeletal Infection Society criteria. Initially, five synovial fluid samples from each group were assessed for quantitative analysis of alpha-defensin using ELISA. Different dilution ratios (1:10, 1:100, 1:500, 1:1000 and 1:5000) were tested based on the predetermined cutoff value of 5.2 mg/L. The dilutions that performed better were used to compare the results of all samples.
resultsFor infected cases, a gradual increase in the dilution of synovial fluid samples led to an equivalent increase in alpha-defensin level. The same was not observed in the aseptic cases. Both 1:1000 and 1:5000 dilutions presented satisfactory results to differentiate infected and aseptic cases. Further analyses were performed using 1:1000 and 1:5000 for all 40 samples. The 1:1000 dilution resulted in a sensitivity of 88.2% (95%CI, 66%-98%) and specificity of 95.7% (95%CI, 79%-99%), whereas the 1:5000 dilution presented a sensitivity of 94.1% (95%CI, 73%-99%) and a specificity of 100% (95%CI, 86%-100%).
conclusionThe synovial fluid dilution had an important influence on the alpha-defensin ELISA results. Dilutions of 1:5000 showed the best performance for the diagnosis of knee PJI. The results of this study set the basis for a more reliable and reproducible alpha-defensin ELISA during the investigation of PJI, contributing to the expansion of this technique in different treatment centers worldwide.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials