ArticleWorld journal of clinical cases2022
Clinical performance evaluation of O-Ring Halcyon Linac: A real-world study.
Article in World journal of clinical cases, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Log file-based treatment efficiency analysis of TrueBeam and Halcyon delivery systems.Journal of applied clinical medical physics · 2026Article
- A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations.Physics and imaging in radiation oncology · 2026Article
- From CBCT to MR-Linac in Image-Guided Prostate Cancer Radiotherapy Towards Treatment Personalization.Current oncology (Toronto, Ont.) · 2025Review
- Multimodal radiotherapy dose prediction using a multi-task deep learning model.Medical physics · 2024Article
- Development of shielding evaluation and management program for O-ring type linear accelerators.Scientific reports · 2024Article
- MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRadiation therapy, especially the development of linear accelerators, plays a key role in cancer management. The fast-rotating coplanar O-ring Halcyon Linac has demonstrated many advantages. The previous literature has mainly focused on the machine parameters and plan quality of Halcyon, with a lack of relevant research on its clinical application.
aimTo evaluate the clinical performance of the O-ring Halcyon treatment system in a real-world application setting.
methodsData from sixty-one patients who were treated with the Halcyon system throughout the entire radiotherapy process in Peking Union Medical College Hospital between August 2019 and September 2020 were retrospectively reviewed. We evaluated the target tumour response to radiotherapy and irradiation toxicity from 1 to 3 mo after treatment. Dosimetric verification of Halcyon plans was performed using a quality assurance procedure, including portal dosimetry, ArcCHECK and point dose measurements for verification of the system delivery accuracy.
resultsOf the 61 patients in the five groups, 16, 12, 7 and 26 patients had complete response, partial response, progressive disease and stable disease, respectively. No increase in the irradiated target tumour volume was observed when separately evaluating the local response. Regarding irradiation toxicity, no radiation-induced deaths were observed. Thirty-eight percent (23/61 patients) had no radiation toxicity after radiotherapy, 56% (34/61 patients) experienced radiation toxicity that resolved after treatment, and 6% (4/61 patients) had irreversible adverse reactions. The average gamma passing rates with a 2% dose difference and 2-mm distance to agreement for IMRT/VMAT/SRT plans were ArcCHECK at 96.4% and portal dosimetry at 96.7%, respectively. All of the validated clinical plans were within 3% for point dose measurements, and Halcyon's ArcCHECK demonstrated a high pass rate of 99.1% ± 1.1% for clinical gamma passing criteria of 3%/3 mm.
conclusionThe O-ring Halcyon Linac could achieve a better therapeutic effect on the target volume by providing accurate treatment delivery plans with tolerable irradiation toxicity.