ArticleAnesthesiology and pain medicine2022
Dural Puncture During Spinal Cord Stimulator Lead Insertion: Analysis of Practice Patterns.
Article in Anesthesiology and pain medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- STIMFIX™ anchoring in percutaneous spinal cord stimulation trials: interim analysis of a multicenter study.Pain management · 2025Trial
- Functional Recovery Following Spinal Cord Stimulation in a Patient Utilizing Prospera Spinal Cord Stimulation System with Multiphase Stimulation.Orthopedic reviews · 2026Article
- Perspective/short review: Adverse events associated with placement of spinal cord stimulators (SCS).Surgical neurology international · 2026Review
- Genicular nerve radiofrequency ablation practice patterns: A survey study of the International Pain and Spine Interventional Society.Interventional pain medicine · 2024Article
- Post Dural Puncture Headache After Spinal Cord Stimulator Lead Insertion Successfully Treated with Occipital Nerve Blocks.Orthopedic reviews · 2024Article
- Biologic Complications Associated with Cylindrical Lead Spinal Cord Stimulator Implants: A Narrative Review.Orthopedic reviews · 2024Article
- Post-dural Puncture Headache After Removal of Trail Spinal Cord Stimulator Leads: A Case Report.Cureus · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Spinal cord stimulation (SCS) is an important modality for intractable pain not amenable to less conservative measures. During percutaneous SCS lead insertion, a critical step is safe access to the epidural space, which can be complicated by a dural puncture. Objectives: In this review, we present and analyze the practices patterns in the event of a dural puncture during a SCS trial or implantation. Methods: We conducted a survey of the practice patterns regarding spinal cord stimulation therapy. The survey was administered to members of the Spine Intervention Society and American Society of Regional Anesthesia specifically inquiring decision making in case of inadvertent dural puncture during spinal cord stimulator lead insertion. Results: A maximum of 193 responded to a question regarding dural punctures while performing a SCS trial and 180 responded to a question regarding dural punctures while performing a SCS implantation. If performing a SCS trial and a dural puncture occurs, a majority of physicians chose to continue the procedure at a different level (56.99%), followed by abandoning the procedure (27.98%), continuing at the same level (10.36%), or choosing another option (4.66%). Similarly, if performing a permanent implantation and a dural puncture occurs, most physicians chose to continue the procedure at a different level (61.67%), followed by abandoning the procedure (21.67%), continuing at the same level (10.56%), or choosing another option (6.11%). Conclusions: Whereas the goals of the procedure would support abandoning the trial but continuing with the permanent in case of inadvertent dural puncture, we found that decision choices were minimally influenced by whether the dural puncture occurred during the trial or the permanent implant. The majority chose to continue with the procedure at a different level while close to a quarter chose to abandon the procedure. This article sets a time stamp in practice patterns from March 20, 2020 to June 26, 2020. These results are based on contemporary SCS practices as demonstrated by this cohort, rendering the options of abandoning or continuing after dural puncture as reasonable methods. Though more data is needed to provide a consensus, providers can now see how others manage dural punctures during SCS procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.