Evidence map›Paper›PMID 36153402›Full record

ArticleScientific reports2022

Microfluidic microwave biosensor based on biomimetic materials for the quantitative detection of glucose.

Mengqi Zhang, Xiaojun Yang, Mengna Ren, Sui Mao, Rajendra Dhakal, Nam-Young Kim, Yuanyue Li, Zhao Yao

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 41 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. [Research progress on point-of-care testing of blood biochemical indexes based on microfluidic technology].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Mengqi ZhangCollege of Micro and Nano Technology, Qingdao University, Qingdao, 266071, China.
Xiaojun YangCollege of Micro and Nano Technology, Qingdao University, Qingdao, 266071, China.
Mengna RenCollege of Micro and Nano Technology, Qingdao University, Qingdao, 266071, China.
Sui MaoCollege of Materials Science and Engineering, Qingdao University, Qingdao, 266071, China.
Rajendra DhakalDepartment of Computer Science and Engineering, Sejong University, Seoul, 05006, Korea.
Nam-Young KimDepartment of Electronic Engineering, Kwangwoon University, Seoul, 01897, Korea.
Yuanyue LiCollege of Micro and Nano Technology, Qingdao University, Qingdao, 266071, China. yyli@qdu.edu.cn.
Zhao YaoCollege of Micro and Nano Technology, Qingdao University, Qingdao, 266071, China. yzh17@qdu.edu.cn.
Qingdao University · CNKwangwoon University · KRSejong University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a microwave microfluidic biosensor for monitoring blood glucose levels. The glucose sensor is a triple ring microstrip patch antenna integrated with a biomimetic microfluidic device capable of measuring a fixed volume of glucose solution. The sensor was utilized to detect 50-500 mg/dL glucose solutions. The interaction of the glucose solution with the electromagnetic field on the patch's surface influences both the resonance frequency and the magnitude of reflection coefficient. The results indicate that the microfluidic device can reduce experimental error and enhance the correlation between glucose concentration, resonant frequency, and reflection coefficient. Finally, the microfluidic sensor had a sensitivity of 0.25 MHz/(mg/dL), a detection limit as low as 7.7 mg/dL, and correlation coefficients of resonance frequency and reflection coefficient with a glucose concentration of 0.996 and 0.984, respectively. The experiment on the sensor's stability verifies the sensor's excellent stability and rapid response (~ 150 ms). Consequently, the device can be used to differentiate the concentration of glucose solutions, as well as to detect blood glucose levels at an early stage.

Indexed as

Biomimetic MaterialsBiosensing TechniquesBlood GlucoseGlucoseMicrofluidicsMicrowavesBlood GlucoseGlucose

Identifiers

PMID36153402
PMCPMC9509396
OpenAlexW4296935336

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials