Gamma ray detection performance of newly developed MAPD-3NM-II photosensor with LaBr

M Holik, F Ahmadov, A Sadigov, G Ahmadov, D Berikov, F Mamedov, J Naghiyev, I Stekl, Z Sadygov, A Mammadli and 3 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.7field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 5 institutions in 3 countries.

M HolikFaculty of Electrical Engineering, University of West Bohemia, Univerzitni 2795/26, 301 00, Pilsen, Czech Republic. michael.holik.cz@gmail.com.
F AhmadovInstitute of Radiation Problems-ANAS, B. Vahabzade Str. 9, AZ1143, Baku, Azerbaijan. farid081211@gmail.com.
A SadigovInstitute of Radiation Problems-ANAS, B. Vahabzade Str. 9, AZ1143, Baku, Azerbaijan.
G AhmadovInstitute of Radiation Problems-ANAS, B. Vahabzade Str. 9, AZ1143, Baku, Azerbaijan.
D BerikovThe Institute of Nuclear Physics, Ibragimova 1, 050032, Almaty, Kazakhstan.
F MamedovInstitute of Experimental and Applied Physics, Czech Technical University in Prague, Husova 240/5, 110 00, Prague, Czech Republic.
J NaghiyevNational Nuclear Research Center Under the MDDT, Baku Shamakhy HW 20 km, Gobu Sett. of Absheron Dist, AZ0100, Baku, Azerbaijan.
I SteklInstitute of Experimental and Applied Physics, Czech Technical University in Prague, Husova 240/5, 110 00, Prague, Czech Republic.
Z SadygovInstitute of Radiation Problems-ANAS, B. Vahabzade Str. 9, AZ1143, Baku, Azerbaijan.
A MammadliNational Nuclear Research Center Under the MDDT, Baku Shamakhy HW 20 km, Gobu Sett. of Absheron Dist, AZ0100, Baku, Azerbaijan.
A GaribliInstitute of Radiation Problems-ANAS, B. Vahabzade Str. 9, AZ1143, Baku, Azerbaijan.
O UrbanFaculty of Electrical Engineering, University of West Bohemia, Univerzitni 2795/26, 301 00, Pilsen, Czech Republic.
J ZichFaculty of Electrical Engineering, University of West Bohemia, Univerzitni 2795/26, 301 00, Pilsen, Czech Republic.
Azerbaijan National Academy of Sciences · AZNational Nuclear Research Center · AZUniversity of West Bohemia · CZCzech Technical University in Prague · CZNational Nuclear Center of the Republic of Kazakhstan · KZ

Funding

Engineering applications of microworld physics CZ.02.1.01/0.0/0.3/16-019/0000766
6 · The paper itself

Abstract

This paper presents the gamma-ray detection performance of the newly developed MAPD-3NM-II type SiPM sensor array (4 [Formula: see text] 4) with [Formula: see text](Ce) scintillator. The gamma-ray spectra of various sources have been measured in the energy range from 26 keV up to 1332 keV. The newly developed array based on MAPD-3NM-II sensors proved [Formula: see text] 22% enhancement in energy resolution in comparison to the former MAPD-3NM-I based array. The energy resolution of 662 keV gamma-rays measured by MAPD-3NM-II was 3.3% while clearly surpassing 4.25% resolution of MAPD-3NM-I predecessor. The enhancement is related to the high PDE of the new MAPD-3NM-II. Obtained results show that the new MAPD-3NM-II demonstrated good energy resolution and linearity in the studied energy region. The energy resolution of the new detector developed based on MAPD-3NM-II was better than all previous products of MAPD.