Evidence map›Paper›PMID 36148583›Full record

ArticleAdvanced healthcare materials2022

Mechanical Stability of Nano-Coatings on Clinically Applicable Electrodes, Generated by Electrophoretic Deposition.

Vaijayanthi Ramesh, Nadine Stratmann, Viktor Schaufler, Svilen D Angelov, Ilona D Nordhorn, Hans E Heissler, Ricardo Martínez-Hincapié, Viktor Čolić, Christoph Rehbock, Kerstin Schwabe and 3 more

Open access · hybridAbstract read
In one paragraph

Article in Advanced healthcare materials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 4 institutions in 1 country.

Vaijayanthi RameshInstitute of Technical Chemistry I, University of Duisburg-Essen and Center for NanoIntegration Duisburg-Essen (CENIDE), 45141, Essen, Germany.ORCID 0000-0003-4753-5064
Nadine StratmannInstitute of Technical Chemistry I, University of Duisburg-Essen and Center for NanoIntegration Duisburg-Essen (CENIDE), 45141, Essen, Germany.
Viktor SchauflerInstitute of Technical Chemistry I, University of Duisburg-Essen and Center for NanoIntegration Duisburg-Essen (CENIDE), 45141, Essen, Germany.
Svilen D AngelovDepartment of Neurosurgery, Hannover Medical School, 30625, Hannover, Germany.
Ilona D NordhornInstitute of Inorganic and Analytical Chemistry, University of Münster, 48149, Münster, Germany.ORCID 0000-0003-3490-131X
Hans E HeisslerDepartment of Neurosurgery, Hannover Medical School, 30625, Hannover, Germany.
Ricardo Martínez-HincapiéElectrochemistry for Energy Conversion, Max-Planck-Institute for Chemical Energy Conversion, 45470, Mulheim an der Ruhr, Germany.
Viktor ČolićElectrochemistry for Energy Conversion, Max-Planck-Institute for Chemical Energy Conversion, 45470, Mulheim an der Ruhr, Germany.
Christoph RehbockInstitute of Technical Chemistry I, University of Duisburg-Essen and Center for NanoIntegration Duisburg-Essen (CENIDE), 45141, Essen, Germany.
Kerstin SchwabeDepartment of Neurosurgery, Hannover Medical School, 30625, Hannover, Germany.
Uwe KarstInstitute of Inorganic and Analytical Chemistry, University of Münster, 48149, Münster, Germany.
Joachim K KraussDepartment of Neurosurgery, Hannover Medical School, 30625, Hannover, Germany.
Stephan BarcikowskiInstitute of Technical Chemistry I, University of Duisburg-Essen and Center for NanoIntegration Duisburg-Essen (CENIDE), 45141, Essen, Germany.ORCID 0000-0002-9739-7272
University of Duisburg-Essen · DEMedizinische Hochschule Hannover · DEMax Planck Institute for Chemical Energy Conversion · DEUniversity of Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The mechanical stability of implant coatings is crucial for medical approval and transfer to clinical applications. Here, electrophoretic deposition (EPD) is a versatile coating technique, previously shown to cause significant post-surgery impedance reduction of brain stimulation platinum electrodes. However, the mechanical stability of the resulting coating has been rarely systematically investigated. In this work, pulsed-DC EPD of laser-generated platinum nanoparticles (PtNPs) on Pt-based, 3D neural electrodes is performed and the in vitro mechanical stability is examined using agarose gel, adhesive tape, and ultrasonication-based stress tests. EPD-generated coatings are highly stable inside simulated brain environments represented by agarose gel tests as well as after in vivo stimulation experiments. Electrochemical stability of the NP-modified surfaces is tested via cyclic voltammetry and that multiple scans may improve coating stability could be verified, indicated by higher signal stability following highly invasive adhesive tape stress tests. The brain sections post neural stimulation in rats are analyzed via laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). Measurements reveal higher levels of Pt near the region stimulated with coated electrodes, in comparison to uncoated controls. Even though local concentrations in the vicinity of the implanted electrode are elevated, the total Pt mass found is below systemic toxicologically relevant concentrations.

Indexed as

Metal NanoparticlesAnimalsPlatinumRatsPlatinumbiocompatibilitybiomaterialscolloidsdeep brain stimulationimpedancelaser ablation in liquids

Identifiers

PMID36148583
PMCPMC11468750
OpenAlexW4296809025

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.