Evidence map›Paper›PMID 36147059›Full record

ArticleAnnals of medicine and surgery (2012)2022

Helical plating for a re-nonunion and a peri-implant fracture after humeral intramedullary nailing: A report of two cases.

Shuya Nohmi, Masahiro Suzuki, Yukiko Sakamoto

Open access · diamondAbstract readCase Reports
In one paragraph

Article in Annals of medicine and surgery (2012), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Shuya NohmiDepartment of Orthopaedic Surgery, Misawa City Hospital, 164-65 Horiguchi, Misawa, Misawa-shi, Aomori, 033-0022, Japan.
Masahiro SuzukiDepartment of Orthopaedic Surgery, Towada City Central Hospital, 14-8 Nishi12-bancho, Towada-shi, Aomori, 034-0093, Japan.
Yukiko SakamotoDepartment of Orthopaedic Surgery, Towada City Central Hospital, 14-8 Nishi12-bancho, Towada-shi, Aomori, 034-0093, Japan.
Towada City Hospital · JPMisawa City Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction and importance: A re-nonunion after failed intramedullary nailing for a nonunion of the humeral shaft and a peri-implant distal humeral fracture with an ununited humeral shaft are rare cases. Therefore, no consensus has been established regarding the treatment strategies. Case presentation: Case 1: An 84-year-old woman presented with humeral shaft re-nonunion after intramedullary nailing. The images revealed callus formation and loosening of the implant, suggesting a lack of mechanical stability. Nail removal and helical plating were performed. One year postoperatively, bony union was achieved. Case 2: A 59-year-old woman presented with a peri-implant distal humeral fracture with an ununited humeral shaft after nailing. Nail removal and helical plating were performed using a minimally invasive plate osteosynthesis (MIPO) technique. The distal humeral fracture was fixed with plates. One year postoperatively, bony union was achieved. Clinical discussion: Imaging findings in Case 1 indicated that nonunion was caused by a lack of mechanical stability. In Case 2, stabilization of the ununited humeral shaft was also needed. Helical plating provides a mechanically strong fixation and prevents damage to the radial nerve and soft tissues. Conclusion: Evaluating the causative factors of nonunions is important. Helical plating provides mechanical stability and is associated with bony union without autologous bone grafting for a re-nonunion of humeral shaft lacking mechanical instability. For a peri-implant distal humeral fracture with an ununited humeral shaft, helical plating with the MIPO technique provides diaphyseal fracture union and enables the minimal length of distal humeral plate fixation.

Indexed as

Case reportHelical plateHumerusPeri-implant fractureRe-nonunion

Identifiers

PMID36147059
PMCPMC9486657
OpenAlexW4293065012

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.