ArticleViruses2022
Early Dynamics of Hepatitis B Virus (HBV)-DNA and Surface Antigen (HBsAg) in Ramp-Up Phase of Viremia: Implications for Performance Evaluation of Blood Screening Assays.
Article in Viruses, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The Common Specifications/EU 2017/746 regulation for market approval of class D in vitro diagnostic devices (IVDs) intended for detection of blood borne viruses requires testing of the International Standard and 10-30 seroconversion panels to demonstrate 'state of the art' assay performance. We examined whether these requirements for performance evaluation are reasonable for HBV-DNA and HBsAg assays. For this purpose, we quantified HBsAg and HBV-DNA (genotype A) in the ramp-up phase of five seroconversion panels and demonstrated a remarkably parallel increase in the Log concentration of both analytes over time. Testing of seroconversion panels by three nucleic acid amplification technology (NAT) methods in multiple replicates and probit analysis with sufficient critical samples from all five panels taken together showed detection limits in copies/mL that were comparable to those on a HBV-DNA genotype A standard dilution panel. This indicates that the viral doubling time in the ramp-up phase is equal above and below the quantification limit of the viral load assay. The geometric mean HBsAg (PRISM) cutoff crossing point was 20 days later than the 50% NAT (Ultrio Plus) conversion point equivalent to 1500 (range: 1100-2200) and 4.8 (CI: 3.7-6.4) HBV-DNA copies/mL, respectively. Analytical sensitivity data of different NAT assay versions obtained over a decade demonstrated that the detection limit on the International Standard is not representative of all genotyped reference samples. From our detailed mathematical analysis, we conclude that HBV-DNA and HBsAg standard dilution series are functionally equivalent to seroconversion panels. A general requirement of a 95% detection limit ≤100 HBV-DNA copies/mL for different viral genotypes would be a better-defined regulation for EU market approval of NAT blood screening assays than the testing of multiple seroconversion panels to claim 'state of the art' performance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.