Evidence map›Paper›PMID 36146394›Full record

ArticleSensors (Basel, Switzerland)2022

Processing Photoplethysmograms Recorded by Smartwatches to Improve the Quality of Derived Pulse Rate Variability.

Adam G Polak, Bartłomiej Klich, Stanisław Saganowski, Monika A Prucnal, Przemysław Kazienko

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Adam G PolakDepartment of Electronic and Photonic Metrology, Wrocław University of Science and Technology, 50-317 Wrocław, Poland.ORCID 0000-0002-9140-1162
Bartłomiej KlichDepartment of Artificial Intelligence, Wrocław University of Science and Technology, 50-370 Wrocław, Poland.ORCID 0000-0001-7840-1830
Stanisław SaganowskiDepartment of Artificial Intelligence, Wrocław University of Science and Technology, 50-370 Wrocław, Poland.ORCID 0000-0003-3607-5920
Monika A PrucnalDepartment of Electronic and Photonic Metrology, Wrocław University of Science and Technology, 50-317 Wrocław, Poland.ORCID 0000-0002-5800-8297
Przemysław KazienkoDepartment of Artificial Intelligence, Wrocław University of Science and Technology, 50-370 Wrocław, Poland.ORCID 0000-0001-5868-356X
Wrocław University of Science and Technology · PL

Funding

Department of Artificial Intelligence, Wrocław University of Science and Technology Statutory fundsNational Science Center 2020/37/B/ST6/03806Polish Ministry of Education and Science CLARIN-PL Project
6 · The paper itself

Abstract

Cardiac monitoring based on wearable photoplethysmography (PPG) is widespread because of its usability and low cost. Unfortunately, PPG is negatively affected by various types of disruptions, which could introduce errors to the algorithm that extracts pulse rate variability (PRV). This study aims to identify the nature of such artifacts caused by various types of factors under the conditions of precisely planned experiments. We also propose methods for their reduction based solely on the PPG signal while preserving the frequency content of PRV. The accuracy of PRV derived from PPG was compared to heart rate variability (HRV) derived from the accompanying ECG. The results indicate that filtering PPG signals using the discrete wavelet transform and its inverse (DWT/IDWT) is suitable for removing slow components and high-frequency noise. Moreover, the main benefit of amplitude demodulation is better preparation of the PPG to determine the duration of pulse cycles and reduce the impact of some other artifacts. Post-processing applied to HRV and PRV indicates that the correction of outliers based on local statistical measures of signals and the autoregressive (AR) model is only important when the PPG is of low quality and has no effect under good signal quality. The main conclusion is that the DWT/IDWT, followed by amplitude demodulation, enables the proper preparation of the PPG signal for the subsequent use of PRV extraction algorithms, particularly at rest. However, post-processing in the proposed form should be applied more in the situations of observed strong artifacts than in motionless laboratory experiments.

Indexed as

PhotoplethysmographySignal Processing, Computer-AssistedAlgorithmsArtifactsElectrocardiographyHeart RateWavelet Analysisartifact reductionbiomedical signal processingECGHRVPPGPRVwearables

Identifiers

PMID36146394
PMCPMC9502353
OpenAlexW4296455979

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.