ArticlePolymers2022
Polymer Conductive Membrane-Based Circular Capacitive Pressure Sensors from Non-Touch Mode of Operation to Touch Mode of Operation: An Analytical Solution-Based Method for Design and Numerical Calibration.
Article in Polymers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- A Circular Touch Mode Capacitive Rainfall Sensor: Analytical Solution and Numerical Design and Calibration.Sensors (Basel, Switzerland) · 2024Article
- A Theoretical Study on Static Gas Pressure Measurement via Circular Non-Touch Mode Capacitive Pressure Sensor.Sensors (Basel, Switzerland) · 2024Article
- An Improved Theory for Designing and Numerically Calibrating Circular Touch Mode Capacitive Pressure Sensors.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Polymer-based conductive membranes play an important role in the development of elastic deflection-based pressure sensors. In this paper, an analytical solution-based method is presented for the design and numerical calibration of polymer conductive membrane-based circular capacitive pressure sensors from non-touch mode of operation to touch mode of operation. The contact problem of a circular membrane in frictionless contact with a rigid flat plate under pressure is analytically solved, and its analytical solution is used for the design of touch mode circular capacitive pressure sensors for the first time. The analytical relationship with input pressure as independent variable and output capacitance as dependent variable is precisely derived and is used for the numerical calibrations of the analytical relationships with input capacitance as the independent variable and output pressure as the dependent variable in order to meet the capacitive pressure sensor mechanism of detecting pressure by measuring capacitance. For the first time, an example showing the design and numerical calibration of a given (given design parameters) polymer conductive membrane-based circular capacitive pressure sensor from non-touch mode of operation to touch mode of operation is provided. Then, the influence of changing several important design parameters on input capacitance-output pressure relationships is comprehensively investigated in order to clarify the desired input-output relationships when changing design parameters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.