Evidence map›Paper›PMID 36145670›Full record

ArticlePharmaceutics2022

Development of an Add-On Device Using 3D Printing for the Enhancement of Drug Administration Efficiency of Dry Powder Inhalers (Accuhaler).

Kittipat Suwanpitak, Lee-Yong Lim, Inderbir Singh, Pornsak Sriamornsak, Thanongsak Thepsonthi, Kampanart Huanbutta, Tanikan Sangnim

Open access · goldAbstract read
In one paragraph

Article in Pharmaceutics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Kittipat SuwanpitakFaculty of Pharmaceutical Sciences, Burapha University, 169, Seansook, Muang, Chonburi 20131, Thailand.
Lee-Yong LimDivision of Pharmacy, School of Allied Health, University of Western Australia, Perth, WA 6009, Australia.ORCID 0000-0002-7307-0742
Inderbir SinghChitkara College of Pharmacy, Chitkara University, Patiala 140401, Punjab, India.ORCID 0000-0002-1860-4246
Pornsak SriamornsakFaculty of Pharmacy, Silpakorn University, Nakhon Pathom 73000, Thailand.ORCID 0000-0002-5525-1494
Thanongsak ThepsonthiFaculty of Engineering, Burapha University, 169, Seansook, Muang, Chonburi 20131, Thailand.
Kampanart HuanbuttaSchool of Pharmacy, Eastern Asia University, Thanyaburi, Pathumthani 12110, Thailand.ORCID 0000-0001-8188-153X
Tanikan SangnimFaculty of Pharmaceutical Sciences, Burapha University, 169, Seansook, Muang, Chonburi 20131, Thailand.ORCID 0000-0002-9332-384X
Burapha University · THChitkara University · INEastern Asia University · THSilpakorn University · THThe University of Western Australia · AU

Funding

Faculty of Pharmaceutical Sciences, Burapha University Rx10/2565
6 · The paper itself

Abstract

The goal of this study was to develop an add-on device for dry powder inhalers (Accuhaler) via 3D printing to improve drug administration efficiency in patients with limited inspiratory capacity, including young children, the elderly, and those with chronic obstructive pulmonary disease. With salmeterol xinafoate and fluticasone propionate as model active pharmaceutical ingredients (API), the emitted API doses were used to assess the effectiveness of the add-on device. The APIs were quantified by an HPLC assay validated for specificity, range, linearity, accuracy, and precision. The motor power of the add-on device could be regulated to moderate fan speed and the air flow in the assembled device. When 50-100% of the fan motor power of the add-on device was used, the emitted dose from the attached dry powder inhaler (DPI) was increased. A computational fluid dynamics application was used to simulate the air and particle flow in the DPI with the add-on device in order to elucidate the operating mechanism. The use of the add-on device combined with a sufficient inhalation flow rate resulted in a larger pressure drop and airflow velocity at the blister pocket. As these characteristics are associated with powder fluidization, entrainment, and particle re-suspension, this innovative add-on device might be utilized to enhance the DPI emitted drug dose for patients with low inspiratory rates and to facilitate the provision of adequate drug doses to achieve the treatment outcomes.

Indexed as

3D printing technologyAccuhalercomputational fluid dynamicsCOPDdry powder inhalers

Identifiers

PMID36145670
PMCPMC9504113
OpenAlexW4296588760

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.